[Long-term effects of permanent pacemaker implantation on tricuspid valve regurgitation].

Zhonghua Yi Xue Za Zhi

Institute of Cardiac Surgery of PLA, Department of Cardiovascular Surgery, Clinical Division of Surgery, Chinese PLA General Hospital, Beijing 100853, China.

Published: August 2012

Objective: To explore the long-term effects of permanent pacemaker implantation (PPI) on tricuspid valve regurgitation (TR) in Chinese patients so as to determine the incidence and related factors, evaluate its effects on heart structure and function and ascertain the exact mechanism of TR after PPI.

Methods: A total of 430 patients undergoing permanent pacemaker replacement at our hospital between January 2000 and June 2011 were recruited. The patients with isolated atrial lead implantation procedures, significant heart valve disease or chronic obstructive pulmonary disease were excluded. The data of 108 patients who had Doppler echocardiograms performed before the first pacemaker implantation procedure and this pacemaker replacement procedure were obtained and retrospectively analyzed. According to the post-implant grade of TR, the patients were divided into two groups: normal tricuspid (n = 79) and abnormal tricuspid (n = 29). Their clinical characteristics and echocardiographic data between two groups were analyzed and compared.

Results: The mean follow-up time (from the first pacemaker implantation) was (13 ± 6) years (range: 4 - 34). Among 108 patients with initially normal tricuspid post-implant, 29 patients (26.9%) developed significant TR during the follow-up. In comparison to those in normal tricuspid group, the patients in abnormal tricuspid group had a longer time from the first pacemaker implantation ((16 ± 7) vs (12 ± 5) years, P = 0.003), more transtricuspid leads (1.31 ± 0.66 vs 1.10 ± 0.30, P = 0.026), larger right atrial size ((38 ± 7) vs (35 ± 4) mm, P = 0.028) and higher prevalence of mild TR and mitral valve regurgitation (MR) pre-implantation (TR: 21% vs 4%, P = 0.015, MR: 28% vs 5%, P = 0.003). The size of right atrium, right ventricle and left atrium in abnormal tricuspid group were more than those in normal tricuspid group. The prevalence of significant MR post-implantation in abnormal tricuspid group was higher than that in normal tricuspid group. The ejection fraction in abnormal tricuspid group was lower than that in normal tricuspid group during the follow-up.

Conclusions: Abnormal TR after PPI during a long-term follow-up is quite common. The related factors include the time interval from the first pacemaker implantation, number of transtricuspid lead, right atrial size, mild TR and MR pre-implantation.

Download full-text PDF

Source

Publication Analysis

Top Keywords

tricuspid group
32
pacemaker implantation
24
normal tricuspid
24
abnormal tricuspid
20
tricuspid
13
permanent pacemaker
12
effects permanent
8
pacemaker
8
tricuspid valve
8
valve regurgitation
8

Similar Publications

(1) Background: There are little data about the differences in clinical and echocardiographic characteristics between elderly (aged ≥ 65 years) and younger patients with acute pulmonary embolism (PE). (2) Methods: Consecutive patients diagnosed with PE in a tertiary hospital were identified. Clinical characteristics, biomarkers and transthoracic echocardiography indices including right ventricular free wall longitudinal strain (RV-FWLS) were recorded.

View Article and Find Full Text PDF

Objective: Percutaneous vegetation debulking has been reported to treat tricuspid valve infective endocarditis (TVIE), but data on feasibility compared with conventional surgical strategies are limited. We aimed to compare short-term outcomes of suction debulking with partial venovenous bypass to conventional open surgery in this population.

Methods: This was a single-center, retrospective study that included all patients with isolated TVIE who underwent suction debulking with partial venovenous bypass or tricuspid valve surgery between January 2010 and December 2022.

View Article and Find Full Text PDF

This study aimed to evaluate the hemodynamic and ventricular performance of neonates with hypoxic-ischemic encephalopathy (HIE) undergoing therapeutic hypothermia using conventional and advanced echocardiographic techniques. This observational, prospective study included 22 neonates with HIE matched with 22 healthy neonates. Echocardiographic studies were performed 24 h after achieving target temperature during hypothermia and 24 h after rewarming.

View Article and Find Full Text PDF

Background: Data supporting the use of transcatheter aortic valve replacement (TAVR) for bicuspid aortic valve (BAV) is limited compared to tricuspid aortic valve (TAV) anatomy, as the BAV anatomy poses unique challenges to prosthesis expansion and symmetric deployment.

Aims: We aim to compare the acute recoil and asymmetry of the SAPIEN-3 valve between BAV and TAV anatomies and their impact on procedural outcomes.

Methods: We conducted a single-center study of patients who underwent TAVR with the SAPIEN-3 valve.

View Article and Find Full Text PDF

Background: The relationship between diastolic function parameters and the severity of coronary artery disease (CAD) is controversial. This study aimed to determine the relationship between left ventricular diastolic function and the severity of CAD.

Methods: This cross-sectional study included 63 patients with Ischemic heart disease (IHD) or those suspected of having IHD, who underwent angiography.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!