Ureteric embolization for lower urinary tract fistulae: use of two amplatzer vascular plugs and N-butyl cyanoacrylate employing the "sandwich" technique.

Cardiovasc Intervent Radiol

Department of Radiology & Medical Imaging, Division of Vascular Interventional Radiology, University of Virginia Health System, 1215 Lee St, PO Box 800170, Charlottesville, VA 22908, USA.

Published: August 2013

Purpose: This study describes and evaluated the effectiveness of occluding distal ureters in the clinical setting of urinary vaginal (vesicovaginal or enterovesicovaginal) fistulae utilizing a new technique which combines Amplatzer vascular plugs and N-butyl cyanoacrylate.

Materials: This is a retrospective study (January 2007-December 2010) of patients with urinary-vaginal fistulae undergoing distal ureter embolization utilizing an Amplatzer-N-butyl cyanoacrylate-Amplatzer sandwich technique. An 8-12-mm type-I or type-II Amplatzer vascular plug was delivered using the sheath and deployed in the ureter distal to the pelvic brim. Instillation of 0.8-1.5 cc of N-butyl cyanoacrylate into ureter proximal to the Amplatzer plug was performed. This was followed by another set of 8-12-mm type-I or type-II Amplatzer vascular plugs in a technique referred to as the "sandwich technique."

Results: Five ureters in three patients were occluded utilizing the above-described technique during the 4-year study period. Mean maximum size Amplatzer used per ureter was 10.8 mm (range, 8-12). One ureter required three Amplatzer plugs and the rest required two. Two patients (3 ureters) were clinically successful with complete resolution of symptoms in 36-48 h. The third patient (2 ureters) was partly successful and required a second Amplatzer-N-butyl cyanoacrylate sandwich technique embolization. The mean clinical follow-up was 11.3 months (range, 1.7-29.2).

Conclusions: The Amplatzer-N-butyl cyanoacrylate-Amplatzer sandwich technique for occluding the distal ureter is safe and effective with a quick (probably due to the N-butyl cyanoacrylate) and durable (probably due to the Amplatzer plugs) clinical response.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-012-0510-1DOI Listing

Publication Analysis

Top Keywords

amplatzer vascular
16
vascular plugs
12
n-butyl cyanoacrylate
12
sandwich technique
12
amplatzer
8
plugs n-butyl
8
occluding distal
8
distal ureter
8
amplatzer-n-butyl cyanoacrylate-amplatzer
8
cyanoacrylate-amplatzer sandwich
8

Similar Publications

Celiac trunk angiography with balloon occlusion of splenic artery for diagnosis and treatment of splenic steal syndrome.

Radiol Case Rep

March 2025

University of Maryland School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Division of Vascular and Interventional Radiology, Baltimore, MD, USA.

Splenic steal syndrome (SSS) post liver transplant is a potential cause of graft dysfunction in the setting of peripheral hepatic arterial bed resistance and redirection of blood flow to a dominant splenic artery resulting in reduction of hepatic arterial inflow. We report utilization of balloon occlusion of the proximal splenic artery as an objective measure to confirm the diagnosis of SSS in a patient with orthotopic liver transplant followed by successful treatment with proximal splenic artery embolization using Gelfoam and Amplatzer vascular plug. Written informed consent for the publication of this case report was obtained from the patient.

View Article and Find Full Text PDF

Delayed surgical management of an Amplatzer device migration into the aortoiliac bifurcation.

J Vasc Surg Cases Innov Tech

February 2025

Department of Vascular Surgery, Aortic Center, Hôpital Marie Lannelongue, Groupe Hospitalier Paris Saint Joseph, INSERM UMR_S 999, Université Paris Saclay, Paris, France.

View Article and Find Full Text PDF

The objective of this study is to evaluate the clinical application and primary outcome of transcatheter embolization using Amplatzer™ Vascular Plug (AVP) Type 2 and Type 4 in different congenital cardiovascular malformations. This is a single-center retrospective observational cohort study. We analyzed clinical and imaging data of 36 patients retrospectively who received transcatheter embolizations of the following malformations using AVP: systemic-to-pulmonary collateral arteries (SPCA), patent ductus arteriosus (PDA), ventricular septal defects (VSD), and aberrant pulmonary sequestration arteries (PSA).

View Article and Find Full Text PDF

Background: The new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease-of-use and procedural results of left atrial appendage closure (LAAC). We aimed to compare procedural results after switching our LAAC program at a tertiary care center with the Amulet device to the Steerable Delivery Sheath, with a control group of LAAC employing the standard sheath.

Methods: The first n = 32 consecutively treated patients at our site using the Amulet device with the Steerable Delivery Sheath were included in this retrospective analysis.

View Article and Find Full Text PDF

Collateral vascular arteries from the descending aorta to the pulmonary arteries are uncommon after arterial switch operation. We describe a case of transposition of the great arteries (TGA) with significant aortopulmonary collateral vessels causing management difficulties after an arterial switch operation. Preoperatively, the presence of collaterals exacerbated aortic diastolic runoff and led to myocardial ischemia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!