Recent changes in regulatory restrictions and social views against animal testing have accelerated development of reliable alternative tests for predicting skin sensitizing potential and potency of many chemicals. Lately, a test battery integrated with different in vitro tests has been suggested as a better approach than just one in vitro test for replacing animal tests. In this study, we created a dataset of 101 test chemicals with LLNA, human cell line activation test (h-CLAT), direct peptide reactivity assay (DPRA) and in silico prediction system. The results of these tests were converted into scores of 0-2 and the sum of individual scores provided the accuracy of 85% and 71% for the potential and potency prediction, compared with LLNA. Likewise, the straightforward tiered system of h-CLAT and DPRA provided the accuracy of 86% and 73%. Additionally, the tiered system showed a higher sensitivity (96%) compared with h-CLAT alone, indicating that sensitizers would be detected with higher reliability in the tiered system. Our data not only demonstrates that h-CLAT can be part of a test battery with other methods but also supports the practical utility of a tiered system when h-CLAT and DPRA are the first screening methods for skin sensitization.