  • The study aimed to evaluate whether resurfacing shoulder arthroplasty successfully restores normal shoulder anatomy while preserving bone structure in patients.
  • It involved 61 patients with various types of shoulder issues, and after an average follow-up of 36 months, improvements in function and specific scores were noted, although some changes to the bone structure were observed.
  • Conclusions indicated that while the surgery mostly maintained normal anatomy and addressed wear, there was a trend toward improper positioning of the prosthesis, which correlated with some patients experiencing renewed pain.

Article Abstract

Background: The goal of a resurfacing shoulder arthroplasty is to reproduce the individual's anatomy while preserving the bone stock of the humeral head. This study investigated the hypothesis that resurfacing the humeral prosthesis restores normal glenohumeral relationships and correlates with the final clinical results.

Materials And Methods: A resurfacing shoulder implant was performed in 61 patients (64 shoulders). Indications were primary osteoarthritis in 26, secondary osteoarthritis in 21, avascular necrosis in 4, rheumatoid arthritis in 4, dysplasia in 4, and for others indications in 5.

Results: At an average of 36 months (range, 24-65) of follow-up , the Constant score reached 68 points and the Quick-Disabilities of Arm, Shoulder and Hand score reached 28 points. Preoperative and postoperative radiographic analysis showed a decrease of the humeral head diameter (51 ± 5 vs 48 ± 5 mm) and of the height of the humeral head (21 ± 4 vs 19 ± 2 mm), without modification of the radius of curvature or the height of the center of rotation. The medial humeral offset increased from 3.3 ± 3.5 to 6.4 ± 3 mm and the lateral offset from 6.8 ± 9 to 10.4 ± 9 mm. The implant was mainly in varus postoperatively compared with preoperative values (122° ± 11° vs 134° ± 7°). Postoperative radiographic analysis and at the last follow-up did not show any significant difference, except for the increase of the depth of the glenoid from 4.2 ± 1.4 to 4.9 ± 1.8 mm.

Conclusions: The resurfacing shoulder arthroplasty reproduces the normal anatomy and compensates glenohumeral wear. However, there was a tendency to position the prosthesis in varus because of technical imperfections. With follow-up, medialization of the humerus with glenoid wear was observed and was correlated in some patients with reappearance of pain.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2012.07.014DOI Listing

Publication Analysis

Top Keywords

resurfacing shoulder
12
humeral head
12
resurfacing humeral
8
humeral prosthesis
8
shoulder arthroplasty
8
score reached
8
reached points
8
postoperative radiographic
8
radiographic analysis
8
resurfacing
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!