A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Visceral adipose tissue quantification using Lunar Prodigy. | LitMetric

A dual-energy X-ray absorptiometry (DXA) application to measure visceral adipose tissue (VAT) in the android region of a total body DXA scan has recently been developed. This new application, CoreScan, has been validated on the Lunar iDXA (GE Healthcare, Madison, WI) densitometer against volumetric computed tomography. The geometric assumptions underlying the CoreScan model are the same on the Prodigy (GE Healthcare, Madison, WI) densitometer. However, differences between the peak X-ray voltage and detector array configurations may lead to differences in VAT quantification. The purpose of this study was to evaluate the agreement of Prodigy and iDXA CoreScan values and to characterize differences in VAT precision between the instruments. Data from volunteers with paired Prodigy and iDXA measurements were used to define empirical adjustments to the VAT algorithm parameters (n=59) and validate performance on Prodigy (n=62). Prodigy VAT measurements were highly correlated to iDXA (r=0.984). The mean of the Prodigy-iDXA VAT volume differences was -13.8cm³ with a 95% confidence interval of -45 to +17cm³. The Bland-Altman 95% limits of agreement for the 2 methods were -252 to +224cm³. Measurement of short-term precision showed that measurement error variance on iDXA was smaller (p<0.01) than Prodigy (coefficient of variance: 7.3% vs 9.8%). Precision results are in agreement with previous reports on the differences between Prodigy and iDXA for body composition measures. Prodigy and iDXA measures of VAT are similar, but the lower precision of the Prodigy may require investigators to target larger changes in VAT.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jocd.2012.09.002DOI Listing

Publication Analysis

Top Keywords

visceral adipose
8
adipose tissue
8
healthcare madison
8
madison densitometer
8
differences vat
8
prodigy idxa
8
prodigy
6
vat
6
idxa
5
tissue quantification
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!