A key bottleneck to high-speed chemical analysis, including hyperspectral imaging and monitoring of dynamic chemical processes, is the time required to collect and analyze hyperspectral data. Here we describe, both theoretically and experimentally, a means of greatly speeding up the collection of such data using a new digital compressive detection strategy. Our results demonstrate that detecting as few as ~10 Raman scattered photons (in as little time as ~30 μs) can be sufficient to positively distinguish chemical species. This is achieved by measuring the Raman scattered light intensity transmitted through programmable binary optical filters designed to minimize the error in the chemical classification (or concentration) variables of interest. The theoretical results are implemented and validated using a digital compressive detection instrument that incorporates a 785 nm diode excitation laser, digital micromirror spatial light modulator, and photon counting photodiode detector. Samples consisting of pairs of liquids with different degrees of spectral overlap (including benzene/acetone and n-heptane/n-octane) are used to illustrate how the accuracy of the present digital compressive detection method depends on the correlation coefficients of the corresponding spectra. Comparisons of measured and predicted chemical classification score plots, as well as linear and non-linear discriminant analyses, demonstrate that this digital compressive detection strategy is Poisson photon noise limited and outperforms total least squares-based compressive detection with analog filters.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aca.2012.10.005 | DOI Listing |
Sci Rep
January 2025
Advanced Glass and Glass Ceramic Research Laboratory, Department of Physics, University of Lucknow, Lucknow, 226007, India.
Recently, 3-D porous architecture of the composites play a key role in cell proliferation, bone regeneration, and anticancer activities. The osteoinductive and osteoconductive properties of β-TCP allow for the complete repair of numerous bone defects. Herein, β-TCP was synthesized by wet chemical precipitation route, and their 3-D porous composites with HBO and Cu nanoparticles were prepared by the solid-state reaction method with improved mechanical and biological performances.
View Article and Find Full Text PDFAnn Vasc Surg
January 2025
Institute of Cardiac and Aortic Disorders, SRM Institutes for Medical Science (SIMS Hospitals), Chennai, India.
Background: Nonocclusive mesenteric ischemia (NOMI), a subtype of acute mesenteric ischemia, is primarily caused by mesenteric arterial vasoconstriction and decreased vascular resistance, leading to impaired intestinal perfusion.Commonly observed after cardiac surgery, NOMI affects older patients with cardiovascular or systemic diseases, accounting for 20-30% of acute mesenteric ischemia cases with a mortality rate of ∼50%. This review explores NOMI's pathophysiology, clinical implications in aortic dissection, and the unmet needs in diagnosis and management, emphasizing its prognostic significance.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China.
The importance of continuous and reliable pulse wave monitoring is constantly being increased in health signal monitoring and disease diagnoses. Flexible pressure sensors with high sensitivity, low hysteresis and fast response time are an effective means for monitoring pulses. Herein, a special wave-shaped layered porous structure of carbonized wood cellulose sponge (CWCS) was constructed based on natural wood (NW).
View Article and Find Full Text PDFSensors (Basel)
January 2025
Beijing Aerospace Automatic Control Institute, Beijing 100854, China.
The traditional method is capable of detecting and tracking stationary and slow-moving targets in a sea surface environment. However, the signal focusing capability of such a method could be greatly reduced especially for those variable-speed targets. To solve this problem, a novel tracking algorithm combining range envelope alignment and azimuth phase filtering is proposed.
View Article and Find Full Text PDFSensors (Basel)
January 2025
College of Computer Science and Technology, Beihua University, No. 3999 East Binjiang Road, Jilin 132013, China.
Aeromagnetic surveying technology detects minute variations in Earth's magnetic field and is essential for geological studies, environmental monitoring, and resource exploration. Compared to conventional methods, residence time difference (RTD) fluxgate sensors deployed on unmanned aerial vehicles (UAVs) offer increased flexibility in complex terrains. However, measurement accuracy and reliability are adversely affected by environmental and sensor noise, including Barkhausen noise.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!