Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: To reduce the risk of human parvovirus B19 (B19V) transmission through contaminated blood for transfusion and plasma-derived products, the Japanese Red Cross (JRC) Blood Centers introduced B19V antigen screening by chemiluminescent enzyme immunoassay (CLEIA-B19V) in 2008.
Study Design And Methods: Donor samples that were positive by CLEIA-B19V screening were tested for B19V DNA. The sensitivity of CLEIA-B19V was tested using samples of all three genotypes and B19V DNA-positive donations. B19V DNA-positive donations and pooled plasma were quantitatively assayed for B19V DNA. B19V DNA-positive donations were phylogenetically analyzed by polymerase chain reaction direct sequencing.
Results: The sensitivity of CLEIA-B19V was inferred to be approximately 6.3 log IU/mL with the genotype samples and 6.4 log IU/mL with B19V DNA-positive donor samples. Of 417 CLEIA-B19V-positive samples from 1,035,560 donations in Hokkaido, Japan, 101 were positive for B19V DNA. The 198 strains of B19V DNA-positive donations in Hokkaido over the past 15 years clustered exclusively with Genotype 1. After introduction of CLEIA-B19V, the viral load for B19V DNA in all 772 pooled plasma for fractionation from donors in nationwide Japan did not exceed 4 log IU/mL.
Conclusion: CLEIA-B19V can detect all three genotypes of B19V (viral load >6.3 log IU/mL) and limit the viral load (<4 log IU/mL) in pooled plasma, and thus such screening has further reduced the risk of transfusion-transmitted B19V infection. These results show that CLEIA-B19V screening at the JRC Blood Centers can be an alternative approach to comply with recommendations regarding B19V in the United States and Europe.