Ultra-short TE (UTE) sequences with radial sampling make it possible to visualize tissues with very short T2 decay times. The UTE sequence acquires an echo signal from the central to the outer parts of k-space and is very sensitive to small trajectory errors. Therefore, k-space errors caused by imperfections in the gradient system performance, such as gradient delay and waveform distortion, must be corrected. During normal clinical use, these errors must be corrected to account for any gradient strength, or image obliquity. Because of time limitation on clinical examination, a simple, robust, and time-efficient correction method for use with UTE is needed. We demonstrated image degradation due to k-space errors by simulation and found that uncontrolled gradient time delays were the dominant cause of image degradation. They could be corrected by using a pre-scan calibration that works by comparison of half and full echo signals. Further improvements in image quality were achieved by using a one-time calibration of gradient waveform approximations that were built from multiple exponential functions and were used during image reconstruction. We have developed a robust UTE correction method that consists of a gradient waveform approximation that follows a short pre-scan for estimating gradient time delay errors.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TMI.2012.2226050DOI Listing

Publication Analysis

Top Keywords

gradient waveform
12
gradient
8
k-space errors
8
correction method
8
image degradation
8
gradient time
8
ute
5
errors
5
image
5
robust ultrashort
4

Similar Publications

The compliant nature of cerebral blood vessels may represent an important mechanical protection for sustained cerebral perfusion during reductions in arterial blood pressure (ABP). However, whether the rise in cerebrovascular compliance (Ci) with falling ABP persists and exhibits a threshold effect remains unknown. Therefore, we analyzed Ci changes during graded head-up tilt (HUT) in individuals with autonomic failure (AF), a group that tolerates graded and progressive reductions in ABP.

View Article and Find Full Text PDF

Nickel (Ni) single-layer coatings were electrodeposited under varying pulse periods (T), duty cycles (θ), and average current densities (i) using four distinct pulse current waveforms: rectangular (Rec), triangular (Tri), ramp-up triangular (Rup), and ramp-down triangular (Rdn). This study demonstrated, through dynamic polarization curves and surface morphology analysis, that single-layer coatings showed relatively good corrosion resistance when deposited at shorter pulse periods, larger duty cycles, and higher average current densities. Moreover, compared with other pulse current waveforms, single-layer coatings electrodeposited at T = 10 ms, θ = 0.

View Article and Find Full Text PDF

We report on continuous high-harmonic generation (HHG) at 1 kHz repetition rate from a liquid-sheet plasma mirror driven by relativistic-intensity near-single-cycle light transients. Through precise control of both the surface plasma density gradient and the driving light waveform, we can produce highly stable and reproducible extreme ultraviolet spectral quasi-continua, expected to correspond to the generation of stable kHz-trains of isolated attosecond pulses in the time domain. This confirms the exciting potential of liquid-sheet targets as one of the building blocks of future high-power attosecond lasers.

View Article and Find Full Text PDF

Background: Spinal cord injury (SCI) often leads to the loss of urinary sensation, making urination difficult. In a previous experiment involving six healthy participants, we measured heartbeat-induced acoustic pulse waves (HAPWs) at the mid-back, calculated time-series power spectra of heart rate gradients at three ultralow/very low frequencies, distinguished and formulated waveform characteristics (one characteristic for each power spectrum, nearly uniform across participants) at times of increased urine in the bladder and heightened urges to urinate, and developed an algorithm with five of these power spectra to identify when urination is needed by extracting the waveform portion (continuous timepoints) where all of the characteristics were consistent with the formulated characteristics. The objective of this study was to verify the validity of the algorithm fed with data from measured HAPW of participants with SCI and to adapt the algorithm for these individuals.

View Article and Find Full Text PDF

Recapitulation of physiologic and pathophysiologic pulsatile CSF flow in purpose-built high-throughput hydrocephalus bioreactors.

Fluids Barriers CNS

December 2024

Department of Chemical Engineering and Materials Science, Wayne State University, 6135 Woodward Avenue, Rm 1413, Detroit, MI, 48202, USA.

Background: Hydrocephalus, an accumulation of cerebrospinal fluid (CSF) in the ventricles of the brain, is often treated via a shunt system to divert the excess CSF to a different compartment; if left untreated, it can lead to serious complications and permanent brain damage. It is estimated that one in every 500 people are born with hydrocephalus. Despite more than 60 years of concerted efforts, shunts still have the highest failure rate of any neurological device requiring follow-up shunt revision surgeries and contributing to the $2 billion cost of hydrocephalus care in the US alone.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!