A comparison of the performance of three visual evoked potential-based methods to estimate visual acuity.

Doc Ophthalmol

Institute for Ophthalmic Research, University of Tübingen, Schleichstrasse 12-16, 72076, Tübingen, Germany.

Published: February 2013

Purpose: To compare visual acuities estimated by three methods of visual evoked potential (VEP) recordings to those obtained by two subjective measures [ETDRS and FrACT (Freiburg acuity test)].

Methods: Ten healthy subjects, aged between 26 and 67 years (mean 43.5), were examined. Best-corrected acuity determined by the ETDRS was between 0.03 and -0.3 logMAR (mean -0.06). Sweep VEPs (sweepVEP), pattern appearance VEPs (pappVEP) and steady-state VEPs (ssVEP) were recorded with two electrode placements (10-20 and Laplace) with best optical correction and with artificially degraded vision using five Bangerter occlusion foils, reducing acuity to about 0.1, 0.22, 0.52, 0.7 and 1.0 logMAR (0.8, 0.6, 0.3, 0.2 and 0.1 decimal scale). Two runs were performed.

Results: ETDRS and FrACT acuities showed good agreement, even though ETDRS seemed to underestimate acuity compared with FrACT at higher acuities. Laplace derivation did not improve any of the VEP-estimated acuities over the 10-20. SweepVEP tended to overestimate lower FrACT acuities, but showed good repeatability. PappVEP placed FrACT acuities into correct or neighboring categories in 87 % of cases. Average ssVEP acuity showed little difference to those of FrACT but variance was larger. ROC analysis for typical clinical application showed good performance for all three methods.

Conclusions: The two subjective measurements of acuities are well correlated. Under the conditions of our experiment, sweepVEP results were less variable and had a better repeatability than ssVEP acuities, whose analysis, in contrast to sweepVEP, can be automated. PappVEP estimates, however, offer a viable alternative, that is, quicker but of lower performance regarding the detection of low acuity thresholds. All methods had a good performance regarding minimum acuity detection if an average of two runs is used.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10633-012-9359-5DOI Listing

Publication Analysis

Top Keywords

fract acuities
12
performance three
8
visual evoked
8
acuity
8
acuities
8
acuities good
8
good performance
8
fract
6
comparison performance
4
visual
4

Similar Publications

Purpose: To evaluate the ability of a novel device using virtual implantation to compare the visual performance of two different types of intraocular lenses (IOLs).

Methods: In this prospective, masked, and randomized clinical trial, the visual performance of monofocal and lowadd bifocal IOLs was compared using a device for virtual implantation called VirtIOL. Eighty patients (< 50 years old with healthy eyes and without cataract) were enrolled in this study.

View Article and Find Full Text PDF

Freiburg vision test (FrACT): optimal number of trials?

Graefes Arch Clin Exp Ophthalmol

September 2024

Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, Freiburg, Germany.

Purpose: Visual acuity is a psychophysical threshold that we want to determine as precisely and efficiently as possible. The Freiburg Vision Test FrACT employs the automated Bayesian "Best PEST" algorithm for this purpose: the next optotype size is always selected to be at threshold based on the information acquired so far, thereby maximizing information gain.

Methods: We assessed the test-retest Limits of Agreement (LoA, Bland & Altman 1986) across 6 to 48 trials in 2 × 78 runs involving 26 participants; visual acuity (in part artificially reduced) ranged from 1.

View Article and Find Full Text PDF

This study aimed to explore the effect of various noise definition criteria in linear extrapolation technique to noise level baseline on steady-state visual evoked potential (SSVEP)-based visual acuity assessment. Four noise definition criteria on frequency-domain, i.e.

View Article and Find Full Text PDF

In order to determine the effect of nystagmus on objective visual acuity (VA) estimates, we compared subjective (VA) and objective (VEP, VA) VA estimates in participants with nystagmus. For this purpose, 20 participants with nystagmus (NY) caused by idiopathic infantile nystagmus, albinism, achiasma or acquired nystagmus were recruited in this study. Estimates of BCVA (best corrected visual acuity) were determined psychophysically (VA; FrACT, Freiburg visual acuity test) and electrophysiologically (VA; EP2000) according to ISCEV (International Society of Clinical Electrophysiology of Vision) guidelines.

View Article and Find Full Text PDF

Introduction: Light's non-visual effects on the biological clock, cognitive performance, alertness, and mental health are getting more recognized. These are primarily driven by blue light, which triggers specific retinal cells containing melanopsin. Traditionally, research on light has relied on correlated color temperature (CCT) as a metric of its biological influence, given that bluer light corresponds to higher Kelvin values.