A simple method for accurate liver volume estimation by use of curve-fitting: a pilot study.

Radiol Phys Technol

Department of Intelligent Systems, Graduate School of Information Sciences, Hiroshima City University, 3-4-1 Ozuka-higashi, Asa-minami-ku, Hiroshima 731-3194, Japan.

Published: January 2013

In this paper, we describe the effectiveness of our curve-fitting method by comparing liver volumes estimated by our new technique to volumes obtained with the standard manual contour-tracing method. Hepatic parenchymal-phase images of 13 patients were obtained with multi-detector CT scanners after intravenous bolus administration of 120-150 mL of contrast material (300 mgI/mL). The liver contours of all sections were traced manually by an abdominal radiologist, and the liver volume was computed by summing of the volumes inside the contours. The section number between the first and last slice was then divided into 100 equal parts, and each volume was re-sampled by use of linear interpolation. We generated 13 model profile curves by averaging 12 cases, leaving out one case, and we estimated the profile curve for each patient by fitting the volume values at 4 points using a scale and translation transform. Finally, we determined the liver volume by integrating the sampling points of the profile curve. We used Bland-Altman analysis to evaluate the agreement between the volumes estimated with our curve-fitting method and the volumes measured by the manual contour-tracing method. The correlation between the volume measured by manual tracing and that estimated with our curve-fitting method was relatively high (r = 0.98; slope 0.97; p < 0.001). The mean difference between the manual tracing and our method was -22.9 cm(3) (SD of the difference, 46.2 cm(3)). Our volume-estimating technique that requires the tracing of only 4 images exhibited a relatively high linear correlation with the manual tracing technique.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12194-012-0186-xDOI Listing

Publication Analysis

Top Keywords

liver volume
12
curve-fitting method
12
manual tracing
12
volumes estimated
8
manual contour-tracing
8
contour-tracing method
8
profile curve
8
estimated curve-fitting
8
measured manual
8
volume
6

Similar Publications

Cine-magnetic resonance imaging (MRI) has been used to track respiratory-induced motion of the liver and tumor and assist in the accurate delineation of tumor volume. Recent developments in compressed sensitivity encoding (SENSE; CS) have accelerated temporal resolution while maintaining contrast resolution. This study aimed to develop and assess hepatobiliary phase (HBP) cine-MRI scans using CS.

View Article and Find Full Text PDF

Choroid plexus cysts on 7T MRI: Relationship to aging and neurodegenerative diseases.

Alzheimers Dement

December 2024

7T Magnetic Resonance Imaging Translational Medical Center, Department of Radiology, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China.

Introduction: The choroid plexus (CP) may play a crucial role in brain degeneration. We aim to assess whether CP cysts (CPCs), defined using ultra-high field magnetic resonance imaging (MRI), relate to aging and neurodegeneration.

Methods: We used multi-sequence 7T MRI to observe CPCs, characterizing their presence and characteristics in healthy younger controls, healthy older controls (OCs), patients with Alzheimer's disease (AD), patients with Parkinson's disease (PD), and patients with uremic encephalopathy.

View Article and Find Full Text PDF

Physiological and growth responses of tambaqui (Colossoma macropomum) fed Croton conduplicatus essential oil and challenged with Aeromonas hydrophila.

Vet Res Commun

December 2024

Universidade Federal do Vale do São Francisco (UNIVASF), Campus Ciências Agrárias, Km 12, BR 407, Lote 543, s/n, Projeto de Irrigação Senador Nilo Coelho, Petrolina, CEP 56300-000, PE, Brazil.

This study aimed to assess the effect of Croton conduplicatus essential oil (CCEO) in diets for tambaqui (Colossoma macropomum) (14.50 ± 0.07 g), a native Amazonian fish.

View Article and Find Full Text PDF

Intravesical Bacillus Calmette-Guérin (BCG) immunotherapy for bladder cancer rarely leads to disseminated BCG infections, most of which occur early after BCG instillations or in immunocompromised patients. We report late-onset disseminated BCG infection after intravesical BCG immunotherapy in a non-immunocompromised patient. A 78-year-old non-immunocompromised man was admitted with fever and hepatosplenomegaly.

View Article and Find Full Text PDF

Purpose: Long axial field-of-view (LAFOV) positron emission tomography/computed tomography (PET/CT) scanners enable high sensitivity and wide anatomical coverage. Therefore, they seem ideal to perform post-selective internal radiation therapy (SIRT) Y scans, which are needed, to confirm that the dose is delivered to the tumors and that healthy organs are spared. However, it is unclear to what extent the use of LAFOV PET is feasible and which dosimetry approaches results in accurate measurements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!