Optical and electrical recordings from isolated coronary-perfused ventricular wedge preparations.

J Mol Cell Cardiol

Masonic Medical Research Laboratory, 2150 Bleecker St., Utica, NY 13501, USA.

Published: January 2013

The electrophysiological heterogeneity that exists across the ventricular wall in the mammalian heart has long been recognized, but remains an area that is incompletely understood. Experimental studies of the mechanisms of arrhythmogenesis in the whole heart often examine the epicardial surface in isolation and thereby disregard transmural electrophysiology. Significant heterogeneity exists in the electrophysiological properties of cardiomyocytes isolated from different layers of the ventricular wall, and given that regional heterogeneities of membrane repolarization properties can influence the electrophysiological substrate for re-entry, the diversity of cell types and characteristics spanning the ventricular wall is important in the study of arrhythmogenesis. For these reasons, coronary-perfused left ventricular wedge preparations have been developed to permit the study of transmural electrophysiology in the intact ventricle. Since the first report by Yan and Antzelevitch in 1996, electrical recordings from the transmural surface of canine wedge preparations have provided a wealth of data regarding the cellular basis for the electrocardiogram, the role of transmural heterogeneity in arrhythmogenesis, and differences in the response of the different ventricular layers to drugs and neurohormones. Use of the wedge preparation has since been expanded to other species and more recently it has also been widely used in optical mapping studies. The isolated perfused wedge preparation has become an important tool in cardiac electrophysiology. In this review, we detail the methodology involved in recording both electrical and optical signals from the coronary-perfused wedge preparation and review the advances in cardiac electrophysiology achieved through study of the wedge.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3535682PMC
http://dx.doi.org/10.1016/j.yjmcc.2012.10.017DOI Listing

Publication Analysis

Top Keywords

wedge preparations
12
ventricular wall
12
wedge preparation
12
electrical recordings
8
ventricular wedge
8
heterogeneity exists
8
transmural electrophysiology
8
cardiac electrophysiology
8
wedge
7
ventricular
6

Similar Publications

Improving colonoscopy quality in the national VA healthcare system.

Contemp Clin Trials

December 2024

San Francisco VA Medical Center, United States of America; Department of Medicine, University of California, San Francisco, CA, United States of America; Measurement Science Quality Enhancement Research Initiative, San Francisco VA Healthcare System, United States of America. Electronic address:

Background: Colorectal cancer (CRC) prevention is a Veterans Affairs (VA) priority. Colonoscopy quality, especially adenoma detection rate (ADR), is critical for effective screening. Our research indicates considerable variation in ADR among VA providers.

View Article and Find Full Text PDF

Regular physical activity (PA) reduces morbidity and mortality in prostate cancer. Prescribing PA in cancer is a necessary awareness but is a real challenge in the case of prostate cancer. Motivational peer support seems to be an innovative strategy for lifestyle change.

View Article and Find Full Text PDF

Objectives: Computed tomography imaging of a sublobar resection specimen may inform intraoperative surgical margin assessment. However, consistency with final pathological margins has not been previously evaluated. In this study, we investigated the concordance between surgical margin measurements by computed tomography versus pathology measurements using an ex vivo sublobar lung resection model.

View Article and Find Full Text PDF

Purpose: The aim of this study was to develop, optimise, train, and evaluate an algorithm for performing Supervised Automated Kinetic Perimetry (SAKP) using digitalised perimetric simulation data.

Methods: The original SAKP algorithm was based on findings from a multicentre study to establish reference values by semi-automated kinetic perimetry (SKP) combined with an automated examination method with moving stimuli ("Program K", developed in Japan). The algorithm evaluated the outer angles of isopter segments and responded to deviations from expected values by placing examination vectors to measure the outer boundaries of the visual field (VF).

View Article and Find Full Text PDF

Background: In low-income and middle-income countries, an estimated 181·9 million (74·6%) preschool-aged children do not receive adequate nurturing care in health, nutrition, protection, learning, and responsive care, thus jeopardising their healthy development across the life course. Working alongside the health sector, multisectoral actions including social protection and education are necessary to achieve child health and development outcomes. Innovations are needed to expand access to high-quality early childhood care and education (ECCE) for young children and opportunities for youth development.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!