Background And Purpose: Computer navigation in total knee arthroplasty is somewhat controversial. We have previously shown that femoral component positioning is more accurate with computed navigation than with conventional implantation techniques, but the clinical impact of this is unknown. We now report the 5-year outcome of our previously reported 2-year outcome study.
Methods: 78 of initially 84 patients (80 of 86 knees) were clinically and radiographically reassessed 5 (5.1-5.9) years after conventional, image-based, and image-free total knee arthroplasty. The methodology was identical to that used preoperatively and at 2 years, including the Knee Society score (KSS) and the functional score (FS), and AP and true lateral standard radiographs.
Results: Although a more accurate femoral component positioning in the navigated groups was obtained, clinical outcome, number of reoperations, KSS, FS, and range of motion were similar between the groups.
Interpretation: The increased costs and time for navigated techniques did not translate into better functional and subjective medium-term outcome compared to conventional techniques.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3555448 | PMC |
http://dx.doi.org/10.3109/17453674.2012.747923 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!