A novel and compact, diode-based, multi-energy soft x-ray (ME-SXR) diagnostic has been developed for the National Spherical Tokamak Experiment. The new edge ME-SXR system tested on NSTX consists of a set of vertically stacked diode arrays, each viewing the plasma tangentially through independent pinholes and filters providing an overlapping view of the plasma midplane which allows simultaneous SXR measurements with coarse sub-sampling of the x-ray spectrum. Using computed x-ray spectral emission data, combinations of filters can provide fast (>10 kHz) measurements of changes in the electron temperature and density profiles providing a method to "fill-in" the gaps of the multi-point Thomson scattering system.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.4731741 | DOI Listing |
J Med Imaging (Bellingham)
December 2024
University of Houston, Department of Physics, Houston, Texas, United States.
Purpose: Photon counting detectors offer promising advancements in computed tomography (CT) imaging by enabling the quantification and three-dimensional imaging of contrast agents and tissue types through simultaneous multi-energy projections from broad X-ray spectra. However, the accuracy of these decomposition methods hinges on precise composite spectral attenuation values that one must reconstruct from spectral micro-CT. Errors in such estimations could be due to effects such as beam hardening, object scatter, or detector sensor-related spectral distortions such as fluorescence.
View Article and Find Full Text PDFRev Sci Instrum
September 2024
Department of Atomic, Molecular and Nuclear Physics, University of Seville, Seville 41012, Spain.
A multi-energy soft x-ray diagnostic is planned to operate in the small aspect ratio tokamak (SMART), consisting of five cameras: one for core measurements, two for edge, and two for divertors. Each camera is equipped with four absolute extreme ultra-violet diodes, with three of them filtered by Ti and Al foils for C and O line emissions, respectively, and Be foils for temperature measurements. In addition, two spectrometers will be installed with a vertical line of sight for impurity control.
View Article and Find Full Text PDFKorean J Radiol
July 2024
Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
Since the emergence of the first photon-counting computed tomography (PCCT) system in late 2021, its advantages and a wide range of applications in all fields of radiology have been demonstrated. Compared to standard energy-integrating detector-CT, PCCT allows for superior geometric dose efficiency in every examination. While this aspect by itself is groundbreaking, the advantages do not stop there.
View Article and Find Full Text PDFDiagnostics (Basel)
May 2024
Department of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy.
Med Phys
February 2024
Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Background: Proton radiotherapy treatment plans are currently restricted by the range uncertainties originating from the stopping power ratio (SPR) prediction based on single-energy computed tomography (SECT). Various studies have shown that multi-energy CT (MECT) can reduce the range uncertainties due to medical implant materials and age-related variations in tissue composition. None of these has directly applied the basis material density (MD) images produced by projection-based MECT systems for SPR prediction.