A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Minimally invasive implantation of the myopore sutureless myocardial pacing lead. | LitMetric

Cardiac resynchronization therapy improves symptoms and survival of patients with congestive heart failure. Usually, the transvenous placement of the left ventricular lead is feasible, but in case of anatomic abnormalities of the coronary sinus, an unintended left phrenic nerve stimulation, a dislodgement of the percutaneous electrode, or a loss of capture of the electrode, surgical treatment should be considered. From January 2010 to September 2011, 15 patients underwent surgical implantation of the left ventricular lead after failure of transvenous placement. The MyoPore sutureless myocardial pacing lead (MSMPL) was implanted through a left minithoracotomy (~5 cm) under selective right lung ventilation. Time of surgery was 38.5 ± 3.0 minutes, and no surgical complications or early deaths are reported so far. After 10.7 ± 8.3 months of follow-up, no cases of late mortality, dislodgement, or loss of capture of the electrode are described. The use of the MSMPL is not novel, although the association with a minimally invasive approach may represent an alternative for a high-risk population. The screw-in of the lead ensures low impedance and threshold of stimulation (1.1 ± 0.6 V at 0.5 milliseconds) both in early and medium terms. In conclusion, in case of failure of the transvenous approach, the MSMPL may be easily implanted through a left minithoracotomy, and the results are noteworthy.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IMI.0b013e3182742496DOI Listing

Publication Analysis

Top Keywords

failure transvenous
12
minimally invasive
8
myopore sutureless
8
sutureless myocardial
8
myocardial pacing
8
pacing lead
8
transvenous placement
8
left ventricular
8
ventricular lead
8
loss capture
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!