Accurate reading with sequential presentation of single letters.

Front Neurosci

Department of Physiology, Monash University Melbourne, VIC, Australia.

Published: November 2012

Rapid, accurate reading is possible when isolated, single words from a sentence are sequentially presented at a fixed spatial location. We investigated if reading of words and sentences is possible when single letters are rapidly presented at the fovea under user-controlled or automatically controlled rates. When tested with complete sentences, trained participants achieved reading rates of over 60 wpm and accuracies of over 90% with the single letter reading (SLR) method and naive participants achieved average reading rates over 30 wpm with greater than 90% accuracy. Accuracy declined as individual letters were presented for shorter periods of time, even when the overall reading rate was maintained by increasing the duration of spaces between words. Words in the lexicon that occur more frequently were identified with higher accuracy and more quickly, demonstrating that trained participants have lexical access. In combination, our data strongly suggest that comprehension is possible and that SLR is a practicable form of reading under conditions in which normal scanning of text is not possible, or for scenarios with limited spatial and temporal resolution such as patients with low vision or prostheses.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3483628PMC
http://dx.doi.org/10.3389/fnins.2012.00158DOI Listing

Publication Analysis

Top Keywords

accurate reading
8
single letters
8
trained participants
8
participants achieved
8
reading rates
8
reading
7
reading sequential
4
sequential presentation
4
single
4
presentation single
4

Similar Publications

Topologically constrained DNA-mediated one-pot CRISPR assay for rapid detection of viral RNA with single nucleotide resolution.

EBioMedicine

January 2025

Department of Chemistry, Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Tsinghua University, New Cornerstone Science Foundation, Beijing, 100084, China. Electronic address:

Background: The widespread and evolution of RNA viruses, such as the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), highlights the importance of fast identification of virus subtypes, particularly in non-laboratory settings. Rapid and inexpensive at-home testing of viral nucleic acids with single-base resolution remains a challenge.

Methods: Topologically constrained DNA ring is engineered as substrates for the trans-cleavage of Cas13a to yield an accelerated post isothermal amplification.

View Article and Find Full Text PDF

Combining automation and expertise: A semi-automated approach to correcting eye-tracking data in reading tasks.

Behav Res Methods

January 2025

Department of Computer Science, Colby College, 4000 Mayflower Hill, Waterville, 04901, Maine, USA.

In reading tasks, drift can move fixations from one word to another or even another line, invalidating the eye-tracking recording. Manual correction is time-consuming and subjective, while automated correction is fast - yet limited in accuracy. In this paper, we present Fix8 (Fixate), an open-source GUI tool that offers a novel semi-automated correction approach for eye-tracking data in reading tasks.

View Article and Find Full Text PDF

Background: Accurate blood pressure monitoring is essential in many clinical scenarios for adults and children and, when continuous measurement is critical, necessitates the insertion of an arterial line. A novel continuous non-invasive arterial pressure monitoring device using a pulse contour algorithm (Pulse Decomposition Analysis), Vitalstream™, is approved by the United States Food and Drug Administration for use in adults. In this study the performance and accuracy of the device compared to intraarterial blood pressure monitoring were assessed in children ages 2-17 undergoing major surgeries.

View Article and Find Full Text PDF

Establishment of a Rapid and Convenient Fluoroimmunoassay Platform Using Antibodies Against PDL1 and HER2.

Curr Issues Mol Biol

January 2025

Department of Biological and Chemical Engineering, Hongik University, Sejong 30016, Republic of Korea.

The development of accurate and high-throughput tools for cancer biomarker detection is crucial for the diagnosis, monitoring, and treatment of diseases. In this study, we developed a simple and rapid fluorescence-linked immunosorbent assay (FLISA) using fluorescent dye-conjugated antibody fragments against programmed cell death ligand 1 (PDL1) and human epithelial growth factor receptor 2 (HER2). We optimized key steps in the FLISA process, including antigen immobilization, blocking, and antibody reaction, reading the assay time to 3 h-significantly faster compared to the 23 h duration of usual FLISA.

View Article and Find Full Text PDF

Comparison of Temporal Artery and Rectal Temperature Measurement During Cooling and Rewarming in Neonates Treated for Hypoxic Ischemic Encephalopathy.

Adv Neonatal Care

January 2025

Author Affiliations: Neonatal Intensive Care Unit, Seattle Children's Hospital, Seattle, WA (Mrs LaBella, Ms Kelly, Mrs Carlin, and Dr Walsh); and Seattle Children's Research Institute, Seattle, WA (Mrs Carlin and Dr Walsh).

Background: Finding an accurate and simple method of thermometry in the neonatal intensive care unit is important. The temporal artery thermometer (TAT) has been recommended for all ages by the manufacturer; however, there is insufficient evidence for the use of TAT in infants, especially to detect hypothermia.

Purpose: To assess the accuracy of the TAT in hypothermic neonates in comparison to a rectal thermometer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?