Background: The antibody characteristics in erythropoiesis-stimulating agent (ESA)-treated patients who develop antibody-mediated pure red cell aplasia (PRCA; amPRCA) can be described as high-affinity, neutralizing anti-ESA antibodies with a mixed immunoglobulin G (IgG) subclass. The characteristics of an early-onset anti-ESA antibody response are not well documented, especially in the months prior to the development of amPRCA. Therefore, a detailed characterization of anti-ESA antibodies was performed in patients in both clinical studies and in a post-market setting. Both baseline and post-dose samples were tested and antibody-positive samples were characterized. Antibody characteristics such as concentration, isotype and specificity were evaluated in subjects with non-neutralizing anti-ESA antibodies and subjects that developed neutralizing anti-ESA antibodies associated with amPRCA.

Methods: Serum samples were analyzed for the presence of anti-ESA antibodies, using a validated surface plasmon resonance (SPR)-based immunoassay or SPRIA.

Results: Among the clinical studies, pre-existing non-neutralizing anti-ESA antibodies were found in 6% of the subjects from clinical studies in nephrology, oncology and congestive heart failure (CHF). After ESA treatment, 2.3% of the subjects developed binding, non-neutralizing antibodies with 0.1% confirmed as having an IgG isotype and were specific to the ESA protein. IgM antibodies were detected at baseline and post-ESA treatment and reported to be specific to the glycosylation of the ESA. No clinical study subjects progressed to amPRCA. In contrast, anti-ESA antibody-positive subjects from the post-market setting with a confirmed IgG subclass were specific to the ESA protein. Subjects that had progressed to amPRCA were noted to have high antibody concentrations with neutralizing activity and a diverse IgG subtype.

Conclusions: A low prevalence of non-neutralizing anti-ESA IgM specific to glycosylation on the ESA and IgG1 antibodies specific to the ESA protein was detected across all clinical patient populations. Patients with amPRCA were noted to have high IgG antibody concentrations, neutralizing antibodies and the presence of anti-ESA IgG4 antibodies.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ndt/gfs392DOI Listing

Publication Analysis

Top Keywords

anti-esa antibodies
28
antibodies
12
clinical studies
12
non-neutralizing anti-esa
12
specific esa
12
esa protein
12
anti-esa
11
antibody characteristics
8
neutralizing anti-esa
8
igg subclass
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!