Fourier-transform infrared (FT-IR) imaging is a well-established modality but requires the acquisition of a spectrum over a large bandwidth, even in cases where only a few spectral features may be of interest. Discrete frequency infrared (DF-IR) methods are now emerging in which a small number of measurements may provide all the analytical information needed. The DF-IR approach is enabled by the development of new sources integrating frequency selection, in particular of tunable, narrow-bandwidth sources with enough power at each wavelength to successfully make absorption measurements. Here, we describe a DF-IR imaging microscope that uses an external cavity quantum cascade laser (QCL) as a source. We present two configurations, one with an uncooled bolometer as a detector and another with a liquid nitrogen cooled mercury cadmium telluride (MCT) detector and compare their performance to a commercial FT-IR imaging instrument. We examine the consequences of the coherent properties of the beam with respect to imaging and compare these observations to simulations. Additionally, we demonstrate that the use of a tunable laser source represents a distinct advantage over broadband sources when using a small aperture (narrower than the wavelength of light) to perform high-quality point mapping. The two advances highlight the potential application areas for these emerging sources in IR microscopy and imaging.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3514576 | PMC |
http://dx.doi.org/10.1021/ac302513f | DOI Listing |
Lancet Reg Health Am
January 2025
Department of Obstetrics & Gynecology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA, USA.
Background: Cesarean delivery remains the most common obstetrical procedure with more than 250,000 patients in the US undergoing cesarean following labor induction annually. Here, we evaluated the impact of prospectively implementing a standardized labor induction protocol on cesarean delivery rates.
Methods: This multi-site type I hybrid effectiveness-implementation study compared 2 years before (PRE) and 2 years after (POST) implementation of a standardized labor induction protocol at two hospitals within the University of Pennsylvania Health System (2018-2022).
J Eval Clin Pract
February 2025
Faculty of Health Sciences, Department of Nursing, Division of Public Health Nursing, Bandırma Onyedi Eylül University, Balıkesir, Turkey.
Aim: This study aimed to translate the Environmental Health Literacy Scale (EHLS) into Turkish and assess its construct validity and internal consistency.
Methods: This research employs a methodological design. The research was conducted during the 2022-2023 academic year with a sample of 500 students from the Faculty of Health Sciences.
J Virol
December 2024
Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.
Previous studies have shown that the majority of long-lived cells harboring persistent HIV-1 proviral genomes originates from viruses circulating in the year prior to antiretroviral therapy (ART) initiation, but a smaller proportion originates from viruses circulating much earlier in untreated infection. These observations suggest that discrete biological factors influence the entry and persistence of viruses into the persistent proviral pool, and there may be periods earlier in untreated infection with increased seeding. Therefore, we examined the timing of formation of the long-lived pool of infected cells that persists during ART in seven women (after a median of 5.
View Article and Find Full Text PDFFront Hum Neurosci
December 2024
Department of Electrical Engineering, Mathematics and Science, University of Gävle, Gävle, Sweden.
Schizophrenia (SZ) is a chronic mental disorder, affecting approximately 1% of the global population, it is believed to result from various environmental factors, with psychological factors potentially influencing its onset and progression. Discrete wavelet transform (DWT)-based approaches are effective in SZ detection. In this report, we aim to investigate the effect of wavelet and decomposition levels in SZ detection.
View Article and Find Full Text PDFMicrosyst Nanoeng
December 2024
Key Laboratory of MEMS of the Ministry of Education, Southeast University, Nanjing, 210096, China.
Piezoelectric resonance sensors are essential to many diverse applications associated with chemical and biological sensing. In general, they rely on continuously detecting the resonant frequency shift of piezoelectric resonators due to analytes accreting on their surfaces in vacuum, gas or fluid. Resolving the small analyte changes requires the resonators with a high quality factor.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!