Background: In 1999, Duzce suffered two consecutive devastating earthquakes above magnitude 7 in August and November. In the present study, we aimed to evaluate the indoor air quality of coffeehouses by determining carbon monoxide (CO) levels and their contributing factors in coffeehouses built before and after the earthquake.

Methods: We conducted our study in 76 Turkish coffeehouses in Duzce in winter (November 2007-March 2008) during rush hours (18:00-23:00). The Turkish coffeehouses included in the study were evaluated under four categories based on smoking status and construction date. The characteristics of the coffeehouses, such as their CO levels and temperatures both indoors and outdoors, were all measured. These analyses were carried out with the SPSS 15.0 program.

Results: The CO levels in Turkish coffeehouses were above the values indicated as being safe by the WHO. While stoves and cooking equipment were determined to contribute to indoor CO levels, cigarettes were found to be the main source. Indoor CO levels at second hour were very strongly correlated (r: 0.84, P<0.001) (r: 0.91, P<0.001) with indoor CO levels at initial and first hour as well as with smoking status (r: 0.69, P<0.001); they were also moderately correlated with the room volume (r: 0.34, P<0.001) and construction materials (r: 0.31, P<0.001) of the coffeehouse.

Conclusion: Elevated CO levels in Turkish coffeehouses indicate the possible presence of other pollutants, particularly when the main source is smoking. In such cases, both individuals and the whole of society are affected negatively in many ways. Therefore, smoking should be prohibited by law in Turkish coffeehouses and national awareness programs should be developed based on peoples' lifestyles. Moreover, the standards for construction and management of Turkish coffeehouses should be improved as well.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3481667PMC

Publication Analysis

Top Keywords

turkish coffeehouses
16
carbon monoxide
8
monoxide levels
8
levels turkish
8
indoor levels
8
coffeehouses
7
levels
6
impacts earthquake
4
earthquake aftermath
4
indoor
4

Similar Publications

Background: In 1999, Duzce suffered two consecutive devastating earthquakes above magnitude 7 in August and November. In the present study, we aimed to evaluate the indoor air quality of coffeehouses by determining carbon monoxide (CO) levels and their contributing factors in coffeehouses built before and after the earthquake.

Methods: We conducted our study in 76 Turkish coffeehouses in Duzce in winter (November 2007-March 2008) during rush hours (18:00-23:00).

View Article and Find Full Text PDF

This study was undertaken to investigate the extent of environmental tobacco smoke (ETS) exposure in coffeehouses, as these are commonly frequented public places in Turkey. From 86 coffeehouses in the 3 districts, 59 coffeehouse workers and 35 hospital staff members (as a control group) were evaluated. Participants answered a questionnaire about demographics, working characteristics, smoking behavior, and ETS exposure during their daily life lives.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!