Noncontact imaging photoplethysmography to effectively access pulse rate variability.

J Biomed Opt

National University of Singapore, Singapore Institute for Neurotechnology, Centre for Life Sciences, Singapore.

Published: June 2013

Noncontact imaging photoplethysmography (PPG) can provide physiological assessment at various anatomical locations with no discomfort to the patient. However, most previous imaging PPG (iPPG) systems have been limited by a low sample frequency, which restricts their use clinically, for instance, in the assessment of pulse rate variability (PRV). In the present study, plethysmographic signals are remotely captured via an iPPG system at a rate of 200 fps. The physiological parameters (i.e., heart and respiration rate and PRV) derived from the iPPG datasets yield statistically comparable results to those acquired using a contact PPG sensor, the gold standard. More importantly, we present evidence that the negative influence of initial low sample frequency could be compensated via interpolation to improve the time domain resolution. We thereby provide further strong support for the low-cost webcam-based iPPG technique and, importantly, open up a new avenue for effective noncontact assessment of multiple physiological parameters, with potential applications in the evaluation of cardiac autonomic activity and remote sensing of vital physiological signs.

Download full-text PDF

Source
http://dx.doi.org/10.1117/1.JBO.18.6.061205DOI Listing

Publication Analysis

Top Keywords

noncontact imaging
8
imaging photoplethysmography
8
pulse rate
8
rate variability
8
low sample
8
sample frequency
8
physiological parameters
8
photoplethysmography effectively
4
effectively access
4
access pulse
4

Similar Publications

Electroacoustic imaging is an imaging modality used to detect electric field energy distribution during electroporation, offering valuable guidance for clinical procedures, particularly in deep tissues. Traditionally, single-element piezoelectric transducers or arrays have been employed for this purpose. However, these piezoelectric sensors are sensitive to electromagnetic interference and require physical contact with the sample through a coupling medium, raising concerns for both clinical and preclinical applications.

View Article and Find Full Text PDF

The terahertz (THz) security scanner offers advantages such as non-contact inspection and the ability to detect various types of dangerous goods, playing an important role in preventing terrorist attacks. We aim to accurately and quickly detect concealed objects in THz security images. However, current object detection algorithms face many challenges when applied to THz images.

View Article and Find Full Text PDF

Meibomian gland alterations in allergic conjunctivitis: insights from a novel quantitative analysis algorithm.

Front Cell Dev Biol

January 2025

Fujian Provincial Hospital, Shengli Clinical Medical College of Fujian Medical University, Fuzhou University Affiliated Provincial Hospital, Fuzhou, China.

Purpose: To investigate the changes in meibomian gland (MG) structure in allergic conjunctivitis (AC) patients using an intelligent quantitative analysis algorithm and to explore the relationship between these changes and clinical parameters.

Methods: A total of 252 eyes from patients with AC and 200 eyes from normal controls were examined. Infrared meibography was performed using the non-contact mode of the Keratograph 5M.

View Article and Find Full Text PDF

Background: This study was developed to determine whether a machine learning model could be developed to assess blood pressure with accuracy comparable to arm cuff measurements.

Methods: A deep learning model was developed based on the UK Biobank dataset and was trained to detect both systolic and diastolic pressure. The hypothesis was formulated after data collection and before the development of the model.

View Article and Find Full Text PDF

Abnormal corneal nerve function and associated disease is a significant public health concern. It is associated with prevalent ocular surface diseases, including dry eye disease. Corneal nerve dysfunction is also a common side effect of refractive surgeries, as well as a symptom of diseases that cause peripheral neuropathies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!