Fractures involving pediatric jaws most often require a splint to prevent the fragments from being displaced; however, impression making presents a challenge. This article describes the fabrication of a surgical splint over an ideal cast, which is subsequently refitted with a tissue conditioner onto the patient's jaw. The highlight of this technique is the elimination of an impression procedure, thereby reducing clinical and laboratory time and easing pain in the child.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1532-849X.2012.00939.xDOI Listing

Publication Analysis

Top Keywords

fabrication surgical
8
surgical splint
8
splint emergency
4
emergency situation
4
situation clinical
4
clinical report
4
report fractures
4
fractures involving
4
involving pediatric
4
pediatric jaws
4

Similar Publications

Endoscopic retrograde cholangiopancreatography training using a silicone simulator fabricated using a 3D printing technique (with videos).

Sci Rep

January 2025

Digestive Disease Center, CHA Bundang Medical Center, CHA University School of Medicine, CHA University, 59 Yatap-ro, Bundang-gu, Seongnam, 13496, Korea.

Endoscopic retrograde cholangiopancreatography (ERCP) training remains challenging. This study used 3D printing techniques to develop and optimize a portable ERCP training simulator and to implement basic and advanced practical techniques. Subsequently, we aimed to determine whether endoscopy trainees acquired proficiency in ERCP techniques and assess any improvements in their skill levels from using this model.

View Article and Find Full Text PDF

Bioelectronics hydrogels for implantable cardiac and brain disease medical treatment application.

Int J Biol Macromol

January 2025

School of Mechanical Engineering, Jiangsu University, No.301 Xuefu Road, Zhenjiang 212013, Jiangsu Province, China. Electronic address:

Hydrogel-based bioelectronic systems offer significant benefits for point-of-care diagnosis, treatment of cardiac and cerebral disease, surgical procedures, and other medical applications, ushering in a new era of advancements in medical technology. Progress in hydrogel-based bioelectronics has advanced from basic instrument and sensing capabilities to sophisticated multimodal perceptions and feedback systems. Addressing challenges related to immune responses and inflammation regulation after implantation, physiological dynamic mechanism, biological toxicology as well as device size, power consumption, stability, and signal conversion is crucial for the practical implementation of hydrogel-based bioelectronics in medical implants.

View Article and Find Full Text PDF

Electrospun robust, biodegradable, bioactive, and nanostructured sutures to accelerate the chronic wound healing.

Biofabrication

January 2025

College of Textiles & Clothing, Qingdao University, 308 Ningxia Road, Qingdao, Qingdao, Shandong, 266071, CHINA.

The design and development of advanced surgical sutures with appropriate structure and abundant bio-functions are urgently required for the chronic wound closure and treatment. In this study, an integrated technique routine combining modified electrospinning with hot stretching process was proposed and implemented to fabricate poly(L-lactic acid) (PLLA) nanofiber sutures, and the Salvia miltiorrhiza Bunge-Radix Puerariae herbal compound (SRHC) was encapsulated into PLLA nanofibers during the electrospinning process to enrich the biofunction of as-generated sutures. All the PLLA sutures loading without or with SRHC were found to exhibit bead-free and highly-aligned nanofiber structure.

View Article and Find Full Text PDF

Physical anatomical models constructed from medical images are valuable research tools for evaluating patient-specific clinical circumstances. For example, 3D models replicating a patient's internal anatomy in the cardiovascular system can be used to validate Computational Fluid Dynamics (CFD) models, which can then be used to identify potential hemodynamic consequences of surgical decisions by providing insight into how blood and vascular tissue mechanics may contribute to disease progression and post-operative complications. Patient-specific models have been described in the literature; however, rapid prototyping models that achieve anatomical accuracy, optical transparency, and thin-walled compliance in a cost and time-effective approach have proven challenging.

View Article and Find Full Text PDF

Special care is required for the management of jaw lesions in pediatric population. The following article describes the decompression technique as the least aggressive approach for the management of pediatric mandibular odontogenic keratocyst. A custom-made acrylic splint was fabricated around teeth, and it was attached to a piece of Foley's catheter to be used as a decompression port.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!