Optokinetic stimulation can break Listing's law without induction of eye movement.

Auris Nasus Larynx

Department of Oto-Rhino-Laryngology, Saitama Medical University, Saitama Medical Center, Kamoda 1981, Kawagoe-shi, Saitama 350-8550, Japan.

Published: August 2013

Objective: Pseudo-images of three-dimensional eye movements captured on an infrared video oculogram can be translated onto a rotational expression around axial vector. This provides a subject's Listing's plane, which moves according to the head's orientation relative to gravity. Optokinetically induced changes in the cognitive gravitational reference frame will affect the context of Listing's plane. The purpose of this study was to estimate the effect of OKS on Listing's plane.

Methods: In this study, we presented vertical optokinetic visual stimulation with fixation targets, which are thought to induce pseudo-inclination of the head, and evaluated changes in the subjects' Listing's plane.

Results: We observed no stimulus-induced movement of Listing's plane that corresponded to the assumed pseudo-recognition of a change in verticality. On the other hand, we did observe vergence movement of Listing's plane (in the yaw plane), which corresponded to exposure to diminished and increased gravitational circumstance. In addition, the thickness of Listing's plane significantly increased with the load of each stimulation.

Conclusion: Vertical OKS leads to a rotation of Listing's plane mainly around a vertical axis. This may represent false exhibition of central compensatory re-weighting with respect to inherent otoconial mass asymmetry resulting from the OKS-mediated loss of the gravity reference. In addition, a OKS-mediated thickening of Listing's plane suggests to us that confusing visual input can reduce the stability of the internal model, which would likely manifest itself as a thickening of Listing's plane. In other words, fluctuation between the build-up and drop-out of vection induced by optokinetic stimulation will cause a thickening of Listing's plane. The thickness of Listing's plane could be a novel clinical parameter for quantitatively evaluating static vestibular function and accuracy of the internal model.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.anl.2012.09.005DOI Listing

Publication Analysis

Top Keywords

listing's plane
40
listing's
13
thickening listing's
12
plane
11
optokinetic stimulation
8
movement listing's
8
plane corresponded
8
thickness listing's
8
internal model
8
stimulation break
4

Similar Publications

Purpose: To explore the significance of changes in anterior chamber depth (ΔACD) and astigmatism between 4 and 8 weeks following uneventful phacoemulsification.

Patients And Methods: Anterior chamber depth (ACD, mm), autorefractometry and subjective refraction were monitored in pseudophakic eyes implanted with non-toric IOLs (group 1, SA60AT, n=36; group 2, SN60WF, n=34; group 3, ICBOO, n=16) and phakic control group (n=30, group 4a, for ACD and autorefractometry) over four weeks. Changes in subjective refractions were compared with repeatability in normal phakic eyes (n=30, group 4b).

View Article and Find Full Text PDF

New results in stereopsis and Listing's law.

Sci Rep

September 2024

Professor Emeritus, Department of Mathematics and Statistics, University of Houston-Downtown, One Main Street, Houston, TX, 77002, USA.

Human eyes' optical components are misaligned. This study presents comprehensive geometric constructions in the binocular system, with the eye model incorporating the fovea that is displaced from the posterior pole and the lens that is tilted away from the eye's optical axis. It extends their previously considered horizontal misalignment with the vertical components.

View Article and Find Full Text PDF

We recently developed a biomimetic robotic eye with six independent tendons, each controlled by their own rotatory motor, and with insertions on the eye ball that faithfully mimic the biomechanics of the human eye. We constructed an accurate physical computational model of this system, and learned to control its nonlinear dynamics by optimising a cost that penalised saccade inaccuracy, movement duration, and total energy expenditure of the motors. To speed up the calculations, the physical simulator was approximated by a recurrent neural network (NARX).

View Article and Find Full Text PDF

Background: Vestibular stimulation causes postural unsteadiness accompanied by a sensation of tilt.

Aims/objectives: The mechanism of the sensation of tilt needs to be assessed by accurate calculation of the rotational axis of torsional eye position under various vestibular stimulations.

Material And Methods: Twenty-two healthy subjects participated in the study.

View Article and Find Full Text PDF

Eyeball simulator for extraocular muscles.

Indian J Ophthalmol

February 2023

General Ophthalmology, Aravind Eye Hospital, Pondicherry, Tamil Nadu, India.

Learning about human eye movements broadens our comprehension of the visuomotor system and aids in the effective management of strabismus. One's clinical practice is improved by a dynamic simulation of human eye movements using physical models of the extraocular muscles (EOMs). We use our eyeball model to teach the basics of strabismus to undergraduate students and ophthalmology residents.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!