AI Article Synopsis

  • Many cancer care settings use distress screening instruments, but their reliability and validity for diverse patient groups are not well established.
  • A systematic review analyzed 148 studies and found that distress screening measures are reliable and effective for White, Latino, and Asian patients.
  • The research highlights a gap in understanding for minority groups, particularly African Americans and immigrants, emphasizing the need for more inclusive research to ensure culturally sensitive healthcare.

Article Abstract

Despite the widespread use of distress screening instruments in cancer care, the reliability and validity of these instruments for a diverse population of cancer patients have not been well established. This is a systematic review of the conceptual and statistical equivalence of screening instruments of 148 psycho-oncology studies that included distress screening instruments. The findings indicate that screening measures of distress have comparable reliability, sensitivity, and specificity for White, Latino, and Asian samples. However, it is unclear if equivalent psychometrics are found among minority ethnic groups (e.g., African American) and immigrants within countries. Given the ethnic diversity among cancer patients and the lack of representation of this diversity in the current research, it is critical that researchers begin to include cancer patients of minority ethnic/racial groups in their samples so that health care providers can screen for distress with cultural sensitivity.

Download full-text PDF

Source
http://dx.doi.org/10.1080/07347332.2012.721489DOI Listing

Publication Analysis

Top Keywords

screening instruments
16
distress screening
12
cancer patients
12
systematic review
8
distress
5
screening
5
instruments
5
patients
4
patients left
4
left systematic
4

Similar Publications

Rapid Determination of Organic and Inorganic Selenium in Poultry Tissues by Internal Extractive Electrospray Ionization Mass Spectrometry.

Anal Chem

January 2025

The Jiangxi Province Key Laboratory for Diagnosis, Treatment, and Rehabilitation of cancer in Chinese Medicine, Jiangxi University of Chinese Medicine, Nanchang 330004, P. R. China.

An online reactive internal extraction electrospray ionization (iEESI) method was developed for the rapid determination of organic and inorganic speciation information for selenium in poultry tissue samples without complex sample pretreatment. The addition of citric acid as a reducing agent to the internal extraction solvent of methanol/acetic acid (99:1, V/V) for iEESI resulted in the reduction of selenate in the sample to selenite, accompanied by the production of malic acid as an oxidation product. The quantitative analysis of selenate was conducted by using malic acid.

View Article and Find Full Text PDF

Remote Follow-Up/Monitoring of Cardiac Implantable Electronic Devices.

Turk Kardiyol Dern Ars

January 2025

Department of Cardiology, University of Health Sciences, Derince Training and Research Hospital, Kocaeli, Türkiye.

Cardiac implantable electronic device (CIED) implantation is a diagnostic and therapeutic method that is being employed on a growing number of patients globally. These devices require long-term follow-up and monitoring, and after implantation, regular follow-ups are conducted at specific intervals. These follow-ups provide crucial information about both the device and the patient, aiding in diagnosis and guiding treatment.

View Article and Find Full Text PDF

Recent Advancements in Localization Technologies for Wireless Capsule Endoscopy: A Technical Review.

Sensors (Basel)

January 2025

Department of Electrical and Computer Systems Engineering, Monash University, Melbourne, VIC 3800, Australia.

Conventional endoscopy is limited in its ability to examine the small bowel and perform long-term monitoring due to the risk of infection and tissue perforation. Wireless Capsule Endoscopy (WCE) is a painless and non-invasive method of examining the body's internal organs using a small camera that is swallowed like a pill. The existing active locomotion technologies do not have a practical localization system to control the capsule's movement within the body.

View Article and Find Full Text PDF

Normalization of Retinal Birefringence Scanning Signals.

Sensors (Basel)

December 2024

Ophthalmic Instrumentation Development Lab, The Wilmer Eye Institute, The Johns Hopkins University School of Medicine, Wilmer 233, 600 N. Wolfe St., Baltimore, MD 21287, USA.

Signal amplitudes obtained from retinal scanning depend on numerous factors. Working with polarized light to interrogate the retina, large parts of which are birefringent, is even more prone to artifacts. This article demonstrates the necessity of using normalization when working with retinal birefringence scanning signals in polarization-sensitive ophthalmic instruments.

View Article and Find Full Text PDF

Accuracy of Rhythm Diagnostic Systems' MultiSense in Detection of Arterial Oxygen Saturation and Respiratory Rate During Hypoxia in Humans: Effects of Skin Color and Device Localization.

Sensors (Basel)

December 2024

Biomedicine Research Center of Strasbourg (CRBS), UR 3072, "Mitochondria, Oxidative Stress and Muscle Plasticity", Faculty of Medicine, University of Strasbourg, 67000 Strasbourg, France.

The continuous monitoring of oxygen saturation (SpO) and respiratory rates (RRs) are major clinical issues in many cardio-respiratory diseases and have been of tremendous importance during the COVID-19 pandemic. The early detection of hypoxemia was crucial since it precedes significant complications, and SpO follow-up allowed early hospital discharge in patients needing oxygen therapy. Nevertheless, fingertip devices showed some practical limitations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!