Evaluation of dried blood spot (DBS) technology versus plasma analysis for the determination of MK-1775 by HILIC-MS/MS in support of clinical studies.

Anal Bioanal Chem

Department of Pharmacokinetics, Pharmacodynamics and Drug Metabolism, Regulated Bioanalysis, Merck Research Laboratories, WP75B-300, West Point, PA 19486, USA.

Published: December 2012

The collection of human blood samples as dried blood spots (DBS) for the pharmacokinetic assessment of investigational drugs in clinical trials offers a number of advantages over conventional plasma sampling, namely, small sample volume, simplified sample handling, and cost-effective shipping and storage. The use of DBS coupled with liquid chromatography-tandem mass spectrometry analysis was evaluated for the quantification of MK-1775, a Wee-1 inhibitor under development as a chemo/radio-sensitizer for the treatment of cancer. The DBS method exhibited an assay performance comparable to that of the existing plasma assay, which is currently used in support of clinical studies. Both assays used the same linear dynamic range of 2-1,000 ng/mL, with a lower limit of quantification of 2 ng/mL. Based on the intra-day assay validation results, the accuracy of the DBS method ranged from 94.0 to 105.0%, with a coefficient of variation of <4.8%. The blood-to-plasma ratio calculated from the DBS data (blood concentrations) and the plasma data (plasma concentrations) was in good agreement with the one obtained from the in vitro assessment using conventional methodology. No significant hematocrit impact on the assay was observed as hematocrit ranged from 16 to 85%. The correlation between the measured MK-1775 concentrations in plasma and that determined in dried blood spots from oncology patients during the ongoing clinical study was discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-012-6440-6DOI Listing

Publication Analysis

Top Keywords

dried blood
8
support clinical
8
clinical studies
8
dbs method
8
dbs
5
evaluation dried
4
blood spot
4
spot dbs
4
dbs technology
4
technology versus
4

Similar Publications

We aimed to assess the impact of splicing variants reported in our laboratory to gain insight into their clinical relevance. A total of 108 consecutive individuals, for whom 113 splicing variants had been reported, were selected for RNA-sequencing (RNA-seq), considering the gene expression in blood. A protocol was developed to perform RNA extraction and sequencing using the same sample (dried blood spots, DBS) provided for the DNA analysis, including library preparation and bioinformatic pipeline analysis.

View Article and Find Full Text PDF

Background And Objectives: Access to blood components in pre-hospital bleeding resuscitation is challenging. Dried plasma is a logistically superior alternative, and new products are emerging. Therefore, we aimed to evaluate laboratory and practical differences in three differently produced dried plasma products.

View Article and Find Full Text PDF

Synthetic antidiabetic drugs are often associated with various adverse side effects, including hypoglycemia, nausea, gastrointestinal disturbances, headaches, and even liver damage. In contrast, plant-derived natural antidiabetic bioactive compounds typically exhibit lower toxicity and fewer side effects and have been reported to aid effectively in diabetes management. These plant extracts regulate diabetes by restoring pancreatic function, enhancing insulin secretion, inhibiting intestinal glucose absorption, and facilitating insulin dependent metabolism.

View Article and Find Full Text PDF

Background: To address high levels of drug-related harms among people who inject drugs (PWID) in Glasgow, a novel contingency management intervention was developed to engage high-risk PWID with four harm reduction measures (known as the WAND initiative: ound care, ssessment of injecting, aloxone, and ried blood-spot test). Our aims were to assess if WAND engaged and re-engaged high-risk PWID.

Methods: Baseline data of WAND participants (n = 831) from 1st Sept-2020 to 30th Aug-2021 were analysed.

View Article and Find Full Text PDF

Acceptability and Feasibility of Self-Collected Dried Blood Spot Specimens for Viral Load Monitoring among Rural Older People Living with HIV.

AIDS Behav

January 2025

Center for AIDS Intervention Research, Department of Psychiatry and Behavioral Medicine, Medical College of Wisconsin, 2153 N. Dr. Martin Luther King Jr. Dr., Milwaukee, WI, 53212, USA.

Self-collected dried blood spot (DBS) samples may be useful in monitoring viral load (VL) in research studies or clinically given that they eliminate the need for participants to travel to study sites or laboratories. Despite this, little information exists about monitoring VL using DBS self-collected at home, and no information exists on DBS for this use among older rural people living with HIV (PLH), a population that could benefit from self-collection given difficulty accessing care. We report on the feasibility and acceptability of self-collected DBS samples, DBS VL results, concordance between self-reported and DBS VL, and factors associated with DBS detectable VL in a rural Southern U.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!