Recent trends in scaffold design have focused on materials that can provide appropriate guidance cues for particular cell types to modulate cell behavior. In this study highly aligned and electrically conductive nanofibers that can simultaneously provide topographical and electrical cues for cells were developed. Thereafter their potential to serve as functional scaffolds for skeletal muscle tissue engineering was investigated. Well-ordered nanofibers, composed of polyaniline (PANi) and poly(ε-caprolactone) (PCL), were electrospun by introducing an external magnetic field in the collector region. Incorporation of PANi into PCL fibers significantly increased the electrical conductivity from a non-detectable level for the pure PCL fibers to 63.6±6.6mS cm(-1) for the fibers containing 3wt.% PANi (PCL/PANi-3). To investigate the synergistic effects of topographical and electrical cues using the electrospun scaffolds on skeletal myoblast differentiation, mouse C2C12 myoblasts were cultured on random PCL (R-PCL), aligned PCL (A-PCL), random PCL/PANi-3 (R-PCL/PANi) and aligned PCL/PANi-3 (A-PCL/PANi) nanofibers. Our results showed that the aligned nanofibers (A-PCL and A-PCL/PANi) could guide myoblast orientation and promote myotube formation (i.e. approximately 40% and 80% increases in myotube numbers) compared with R-PCL scaffolds. In addition, electrically conductive A-PCL/PANi nanofibers further enhanced myotube maturation (i.e. approximately 30% and 23% or 15% and 18% increases in the fusion and maturation indices) compared with non-conductive A-PCL scaffolds or R-PCL/PANi. These results demonstrated that a combined effect of both guidance cues was more effective than an individual cue, suggesting a potential use of A-PCL/PANi nanofibers for skeletal muscle regeneration.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.actbio.2012.10.024 | DOI Listing |
Molecular junctions (MJs) are celebrated nanoelectronic devices for mimicking conventional electronic functions, including rectifiers, sensors, wires, switches, transistors, negative differential resistance, and memory, following an understanding of charge transport mechanisms. However, capacitive nanoscale molecular junctions are rarely seen. The present work describes electrochemically (E-Chem) grown covalently attached molecular thin films of 10, 14.
View Article and Find Full Text PDFChem Sci
January 2025
J. Mike Walker '66 Department of Mechanical Engineering, Texas A&M University College Station TX 77843 USA
This perspective work examines the current advancements in integrated CO capture and electrochemical conversion technologies, comparing the emerging methods of (1) electrochemical reactive capture (eRCC) though amine- and (bi)carbonate-mediated processes and (2) direct (flue gas) adsorptive capture and conversion (ACC) with the conventional approach of sequential carbon capture and conversion (SCCC). We initially identified and discussed a range of cell-level technological bottlenecks inherent to eRCC and ACC including, but not limited to, mass transport limitations of reactive species, limitation of dimerization, impurity effects, inadequate generation of CO to sustain industrially relevant current densities, and catalyst instabilities with respect to some eRCC electrolytes, amongst others. We followed this with stepwise perspectives on whether these are considered intrinsic challenges of the technologies - otherwise recommendations were disclosed where appropriate.
View Article and Find Full Text PDFFront Robot AI
January 2025
School of Metallurgy and Materials, University of Birmingham, Birmingham, United Kingdom.
Introduction: The transition to electric vehicles (EVs) has highlighted the need for efficient diagnostic methods to assess the state of health (SoH) of lithium-ion batteries (LIBs) at the end of their life cycle. Electrochemical Impedance Spectroscopy (EIS) offers a non-invasive technique for determining battery degradation. However, automating this process in industrial settings remains a challenge.
View Article and Find Full Text PDFFront Pediatr
January 2025
Division of Pediatric Cardiology, Division of Pediatrics, Children's Mercy Hospital, University of Missouri-Kansas City, Kansas City, MO, United States.
Background: In adolescents and adults with tetralogy of Fallot (TOF), right ventricle (RV) electromechanical dyssynchrony (EMD) due to right bundle branch block (RBBB) is associated with reduced exercise capacity and RV dysfunction. While the development of RBBB following surgical repair of tetralogy of Fallot (rTOF) is a frequent sequela, it is not known whether EMD is present in every patient immediately following rTOF. The specific timing of the onset of RBBB following rTOF therefore provides an opportunity to assess whether acute RBBB is associated with the simultaneous acquisition of EMD.
View Article and Find Full Text PDFImaging Neurosci (Camb)
April 2024
Department of Electrical Engineering, Columbia University, New York, NY, United States.
Listeners with hearing loss have trouble following a conversation in multitalker environments. While modern hearing aids can generally amplify speech, these devices are unable to tune into a target speaker without first knowing to which speaker a user aims to attend. Brain-controlled hearing aids have been proposed using auditory attention decoding (AAD) methods, but current methods use the same model to compare the speech stimulus and neural response, regardless of the dynamic overlap between talkers which is known to influence neural encoding.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!