Unenhanced MR angiography of renal arteries: 51 patients.

AJR Am J Roentgenol

Department of Radiology B, Centre Hospitalier Universitaire Gabriel Montpied, 58 rue Montalembert, 63003, Clermont-Ferrand, France.

Published: November 2012

Objective: The purpose of this research was to assess the feasibility and performance of an unenhanced 3D balanced steady-state free precession (SSFP) sequence, compared with contrast-enhanced MR angiography (CEMRA), which is the reference standard to detect and quantify renal artery stenoses (RAS).

Subjects And Methods: Fifty-one patients were included in this prospective study. Balanced SSFP sequence (Native) and CEMRA were performed using a 1.5-T magnet. Signal quality and stenosis grade were assessed per segment for renal arteries and for ostia of celiac trunk and superior mesenteric artery (SMA). We compared signal quality of Native and CEMRA. Sensitivity, specificity, negative predictive value (NPV), and accuracy were also calculated.

Results: Evaluation involved 114 renal arteries, 51 celiac trunks, and 51 SMAs. By use of CEMRA, 20 significant stenoses were found for renal arteries, 10 stenoses and three occlusions for celiac trunk, and three stenoses for SMA. At artery-by-artery analysis, sensitivity, specificity, accuracy, and NPV of the balanced SSFP sequence in detecting stenosis were respectively 85%, 96%, 94%, and 96% for renal arteries; 100%, 97%, 98%, and 100% for celiac trunk; and 100%, 100%, 100%, and 100% for SMA. No significant difference of signal quality was found for the entire examination and for the different segments evaluated except for hilar and intrarenal branches, which showed better signal quality on balanced SSFP sequence.

Conclusion: The NPV results in our study suggest that unenhanced balanced SSFP MR angiography can be the first-choice imaging method to exclude RAS in patients at high risk of nephrogenic systemic fibrosis. However, when stenosis is found, other imaging modalities are necessary for better estimation.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.12.8513DOI Listing

Publication Analysis

Top Keywords

renal arteries
20
balanced ssfp
16
signal quality
16
ssfp sequence
12
celiac trunk
12
100% 100%
12
unenhanced balanced
8
native cemra
8
sensitivity specificity
8
renal
6

Similar Publications

In this study, the kidneys of ground squirrels (hibernated and nonhibernated), rabbits, and rats were examined macro and microanatomically. Kidney morphology was investigated by stereo microscopy, light microscopy, and scanning electron microscopy. Triple and immunohistochemical staining were performed for light microscopic examinations.

View Article and Find Full Text PDF

Background: Hemorrhage is the most common and dangerous complication after percutaneous nephrolithotripsy (PCNL). Therefore, this study introduces the management experience of bleeding complications in our center.

Methods: This retrospective study included 77 patients with severe bleeding after PCNL.

View Article and Find Full Text PDF

Whey Protein-Based Hydrogel Microspheres for Endovascular Embolization.

ACS Appl Bio Mater

January 2025

Department of Radiology, University of Minnesota, Minneapolis, Minnesota 55455, United States.

Transarterial embolization (TAE) is an image-guided, minimally invasive procedure for treating various clinical conditions by delivering embolic agents to occlude diseased arteries. Conventional embolic agents focus on vessel occlusion but can cause unintended long-term inflammation and ischemia in healthy tissues. Next-generation embolic agents must exhibit biocompatibility, biodegradability, and effective drug delivery, yet some degradable microspheres degrade too quickly, leading to the potential migration of fragments into distal blood vessels causing off-target embolization.

View Article and Find Full Text PDF

Background: Vascular calcification is highly prevalent and associated with mortality in hemodialysis patients. However, extreme splanchnic arterial calcification in calciphylaxis with poor prognosis raises questions regarding the reliability of previous vascular calcification scoring methods. Therefore, this study aimed to examine the distribution characteristics of abdominal aortic branch calcification and identify a more reliable predictor of mortality in hemodialysis patients.

View Article and Find Full Text PDF

Objectives: To evaluate the function of kidneys with renal artery stenosis using multiparametric magnetic resonance imaging, assess the diagnostic efficacy of multiparametric magnetic resonance imaging for single kidney dysfunction.

Materials And Methods: Renal multiparametric magnetic resonance imaging was performed on 62 patients with RAS using the Philips Ingenia CX 3.0 T MRI machine.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!