The goal of this work was to experimentally quantify the geometric accuracy of a novel real-time 3D target localization method using sequential kV imaging combined with respiratory monitoring for clinically realistic arc and static field treatment delivery and target motion conditions. A general method for real-time target localization using kV imaging and respiratory monitoring was developed. Each dimension of internal target motion T(x, y, z; t) was estimated from the external respiratory signal R(t) through the correlation between R(t(i)) and the projected marker positions p(x(p), y(p); t(i)) on kV images by a state-augmented linear model: T(x, y, z; t) = aR(t) + bR(t - τ) + c. The model parameters, a, b, c, were determined by minimizing the squared fitting error ∑‖p(x(p), y(p); t(i)) - P(θ(i)) · (aR(t(i)) + bR(t(i) - τ) + c)‖(2) with the projection operator P(θ(i)). The model parameters were first initialized based on acquired kV arc images prior to MV beam delivery. This method was implemented on a trilogy linear accelerator consisting of an OBI x-ray imager (operating at 1 Hz) and real-time position monitoring (RPM) system (30 Hz). Arc and static field plans were delivered to a moving phantom programmed with measured lung tumour motion from ten patients. During delivery, the localization method determined the target position and the beam was adjusted in real time via dynamic multileaf collimator (DMLC) adaptation. The beam-target alignment error was quantified by segmenting the beam aperture and a phantom-embedded fiducial marker on MV images and analysing their relative position. With the localization method, the root-mean-squared errors of the ten lung tumour traces ranged from 0.7-1.3 mm and 0.8-1.4 mm during the single arc and five-field static beam delivery, respectively. Without the localization method, these errors ranged from 3.1-7.3 mm. In summary, a general method for real-time target localization using kV imaging and respiratory monitoring has been experimentally investigated for arc and static field delivery. The average beam-target error was 1 mm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3701090PMC
http://dx.doi.org/10.1088/0031-9155/57/22/7395DOI Listing

Publication Analysis

Top Keywords

localization method
20
real-time target
16
target localization
16
respiratory monitoring
16
arc static
12
static field
12
method
8
method sequential
8
sequential imaging
8
imaging combined
8

Similar Publications

Cerebral autosomal-dominant arteriopathy, subcortical infarcts, and leukoencephalopathy (CADASIL) is the most prevalent monogenic inherited cause of cerebral small-vessel disease. Despite its prevalence, there is currently no proven therapy to prevent or reverse the progression of the disease. This study aimed to characterize the functional integrity of long white matter tracts in CADASIL transgenic mice, both with and without focal white matter lesions in the corpus callosum added on, utilizing optical resting-state functional connectivity imaging alongside behavioral examinations.

View Article and Find Full Text PDF

XOR-Derived ROS in Tie2-Lineage Cells Including Endothelial Cells Promotes Aortic Aneurysm Progression in Marfan Syndrome.

Arterioscler Thromb Vasc Biol

January 2025

Department of Cardiovascular Medicine, The University of Tokyo, Bunkyo-ku, Japan. (H. Yagi, H.A., Q.L., A.S.-K., M.U., H.K., R.M., A.S., S.O., H.T., Norifumi Takeda, I.K.).

Background: Marfan syndrome (MFS) is an inherited disorder caused by mutations in the gene encoding fibrillin-1, a matrix component of extracellular microfibrils. The main cause of morbidity and mortality in MFS is thoracic aortic aneurysm and dissection, but the underlying mechanisms remain undetermined.

Methods: To elucidate the role of endothelial XOR (xanthine oxidoreductase)-derived reactive oxygen species in aortic aneurysm progression, we inhibited in vivo function of XOR either by endothelial cell (EC)-specific disruption of the gene or by systemic administration of an XOR inhibitor febuxostat in MFS mice harboring the missense mutation p.

View Article and Find Full Text PDF

Objective: To evaluate the adoption, effectiveness and cost-effectiveness of digital health interventions for rheumatic disease management.

Methods: Between 25 May 2024 and 2 June 2024, we systematically searched PubMed®, Scopus, ClinicalTrials.gov, the Global Observatory for eHealth and the World Bank Open Knowledge Repository for randomized controlled trials (RCTs) evaluating digital health interventions for rheumatic disease management.

View Article and Find Full Text PDF

Purpose: This study aims to validate and revise the Spot Vision Screener referral criteria for detecting amblyopia risk factors (ARFs), visually significant refractive error (VSRE), and amblyopia.

Methods: In clinics, we gathered data from children aged 12 months to 7 years. The validity of the cut-off values was assessed using receiver operating characteristic (ROC) curves, with cycloplegic retinoscopy serving as a reference.

View Article and Find Full Text PDF

Purpose: Cysticercosis, caused by Taenia solium larvae, can affect various ocular and extraocular structures, leading to significant morbidity. Ultrasound B-scan imaging plays a pivotal role in diagnosing and classifying cysticercosis lesions. The aim of the study was to describe the ultrasound B-scan characteristics of ocular and extraocular cysticercosis, proposing a classification system based on anatomical localization to enhance understanding and management.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!