Objectives: The purpose of this study was to evaluate the accuracy, agreement, and reliability of 4-dimensional sonography using spatiotemporal image correlation (STIC) in fetal cardiac measurements during the second and third trimesters.

Methods: Four-dimensional cardiac STIC volumes were acquired from 150 low-risk singleton pregnancies at gestational ages of 18 to 38 weeks. A total of 11 dimensions of the fetal heart and great vessels were analyzed by two different observers. Accuracy was assessed by comparing the measurements acquired by 4-dimensional STIC with those determined by 2-dimensional echocardiography by calculating the mean error and mean percent error and depicted by Bland-Altman plots. Absolute agreement and reliability of STIC-based measurements were evaluated on the basis of an intraclass correlation coefficient (ICC).

Results: For STIC-based measurements of cardiac dimensions, good accuracy was achieved by the two experienced observers (mean percent error, -3.10% to 0.87% for observer A; -2.49% to -0.33% for observer B), and absolute agreement was almost perfect (ICC, 95% confidence interval, 0.916-0.993 for observer A; 0.957-0.990 for observer B). Interobserver ICCs among the two observers were between 0.909 and 0.990 (95% confidence interval), whereas intraobserver ICCs for observer A were between 0.894 and 0.989, and those for observer B were between 0.893 and 0.985, showing no significant differences in the reliability of SITC with regard to observers.

Conclusions: Four-dimensional sonography with STIC is a feasible and accurate method for fetal cardiac dimension measurements in the second and third trimesters. It is in good agreement with 2-dimensional echocardiography and can be performed by different observers.

Download full-text PDF

Source
http://dx.doi.org/10.7863/jum.2012.31.11.1719DOI Listing

Publication Analysis

Top Keywords

agreement reliability
12
fetal cardiac
12
accuracy agreement
8
cardiac measurements
8
spatiotemporal image
8
image correlation
8
measurements second
8
second third
8
2-dimensional echocardiography
8
percent error
8

Similar Publications

Self-efficacy scale for university teaching in virtual environments, SSUTVE.

Heliyon

January 2025

Instituto de Investigación FCCTP, Facultad de Ciencias de la Comunicación, Turismo y Psicología, Universidad de San Martín de Porres, Lima, Peru.

Self-efficacy is relevant in explaining performance and well-being in different domains of human behaviour. Despite this need, there are no instruments that assess self-efficacy in university teaching in virtual environments. Therefore, the objective of this study was to design the Self-Efficacy Scale for University Teaching in Virtual Environments (SSUTVE) and analyse its psychometric properties.

View Article and Find Full Text PDF

Purposes: The objective was to evaluate the accuracy of a novel CT dynamic angiographic imaging (CT-DAI) algorithm for rapid fractional flow reserve (FFR) measurement in patients with coronary artery disease (CAD).

Materials And Methods: This retrospective study included 14 patients (age 58.5 ± 10.

View Article and Find Full Text PDF

Objective: To assess the reproducibility and reliability of the pink (PES) and white esthetic scores (WES) using digital images and the intra- and inter-examiner agreement among different clinical backgrounds and assessment methods.

Material And Methods: Standardized intraoral images were obtained from adult subjects with an implant-supported single-tooth fixed dental prosthesis located in the maxillary esthetic zone using a digital camera and a true-color intraoral scanner. According to the PES and WES criteria, the images were evaluated by 20 calibrated evaluators, 5 prosthodontists, 5 periodontists, 5 undergraduates, and 5 oral surgeons.

View Article and Find Full Text PDF

Reliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study.

JMIR Mhealth Uhealth

January 2025

ULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.

Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non-laboratory-controlled conditions with actual specific and various physical activity movements.

Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities.

View Article and Find Full Text PDF

Background: Diagnosing headache disorders poses significant challenges, particularly in primary and secondary levels of care (PSLC), potentially leading to misdiagnosis and underdiagnosis. This study evaluates diagnostic agreement for migraine, tension-type headache (TTH), and cluster headache (CH) between PSLC and tertiary care (TLC) and assesses adherence to the International Classification of Headache Disorders 3rd edition (ICHD-3) guidelines.

Methods: A retrospective, cross-sectional analysis was conducted at Charité - Universitätsmedizin Berlin's tertiary headache center.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!