Objectives: The purpose of this study was to evaluate the accuracy, agreement, and reliability of 4-dimensional sonography using spatiotemporal image correlation (STIC) in fetal cardiac measurements during the second and third trimesters.
Methods: Four-dimensional cardiac STIC volumes were acquired from 150 low-risk singleton pregnancies at gestational ages of 18 to 38 weeks. A total of 11 dimensions of the fetal heart and great vessels were analyzed by two different observers. Accuracy was assessed by comparing the measurements acquired by 4-dimensional STIC with those determined by 2-dimensional echocardiography by calculating the mean error and mean percent error and depicted by Bland-Altman plots. Absolute agreement and reliability of STIC-based measurements were evaluated on the basis of an intraclass correlation coefficient (ICC).
Results: For STIC-based measurements of cardiac dimensions, good accuracy was achieved by the two experienced observers (mean percent error, -3.10% to 0.87% for observer A; -2.49% to -0.33% for observer B), and absolute agreement was almost perfect (ICC, 95% confidence interval, 0.916-0.993 for observer A; 0.957-0.990 for observer B). Interobserver ICCs among the two observers were between 0.909 and 0.990 (95% confidence interval), whereas intraobserver ICCs for observer A were between 0.894 and 0.989, and those for observer B were between 0.893 and 0.985, showing no significant differences in the reliability of SITC with regard to observers.
Conclusions: Four-dimensional sonography with STIC is a feasible and accurate method for fetal cardiac dimension measurements in the second and third trimesters. It is in good agreement with 2-dimensional echocardiography and can be performed by different observers.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.7863/jum.2012.31.11.1719 | DOI Listing |
Heliyon
January 2025
Instituto de Investigación FCCTP, Facultad de Ciencias de la Comunicación, Turismo y Psicología, Universidad de San Martín de Porres, Lima, Peru.
Self-efficacy is relevant in explaining performance and well-being in different domains of human behaviour. Despite this need, there are no instruments that assess self-efficacy in university teaching in virtual environments. Therefore, the objective of this study was to design the Self-Efficacy Scale for University Teaching in Virtual Environments (SSUTVE) and analyse its psychometric properties.
View Article and Find Full Text PDFRadiol Adv
October 2024
Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.
Purposes: The objective was to evaluate the accuracy of a novel CT dynamic angiographic imaging (CT-DAI) algorithm for rapid fractional flow reserve (FFR) measurement in patients with coronary artery disease (CAD).
Materials And Methods: This retrospective study included 14 patients (age 58.5 ± 10.
J Esthet Restor Dent
January 2025
Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland.
Objective: To assess the reproducibility and reliability of the pink (PES) and white esthetic scores (WES) using digital images and the intra- and inter-examiner agreement among different clinical backgrounds and assessment methods.
Material And Methods: Standardized intraoral images were obtained from adult subjects with an implant-supported single-tooth fixed dental prosthesis located in the maxillary esthetic zone using a digital camera and a true-color intraoral scanner. According to the PES and WES criteria, the images were evaluated by 20 calibrated evaluators, 5 prosthodontists, 5 periodontists, 5 undergraduates, and 5 oral surgeons.
JMIR Mhealth Uhealth
January 2025
ULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.
Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non-laboratory-controlled conditions with actual specific and various physical activity movements.
Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities.
J Headache Pain
January 2025
Department of Neurology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
Background: Diagnosing headache disorders poses significant challenges, particularly in primary and secondary levels of care (PSLC), potentially leading to misdiagnosis and underdiagnosis. This study evaluates diagnostic agreement for migraine, tension-type headache (TTH), and cluster headache (CH) between PSLC and tertiary care (TLC) and assesses adherence to the International Classification of Headache Disorders 3rd edition (ICHD-3) guidelines.
Methods: A retrospective, cross-sectional analysis was conducted at Charité - Universitätsmedizin Berlin's tertiary headache center.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!