A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biorecognition on graphene: physical, covalent, and affinity immobilization methods exhibiting dramatic differences. | LitMetric

Biorecognition on graphene: physical, covalent, and affinity immobilization methods exhibiting dramatic differences.

Chem Asian J

Division of Chemistry & Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore 637371, Singapore.

Published: January 2013

The preparation of biorecognition layers on the surface of a sensing platform is a very crucial step for the development of sensitive and selective biosensors. Different protocols have been used thus far for the immobilization of biomolecules onto various electrode surfaces. In this work, we investigate how the protocol followed for the immobilization of a DNA aptamer affects the performance of the fabricated thrombin aptasensor. Specifically, the differences in selectivity and optimum amount of immobilized aptamer of the fabricated aptasensors adopting either physical, covalent, or affinity immobilization were compared. It was discovered that while all three methods of immobilization uniformly show a similar optimum amount of immobilized aptamer, physical, and covalent immobilization methods exhibit higher selectivity than affinity immobilization. Hence, it is believed that our findings are very important in order to optimize and improve the performance of graphene-based aptasensors.

Download full-text PDF

Source
http://dx.doi.org/10.1002/asia.201200756DOI Listing

Publication Analysis

Top Keywords

physical covalent
12
affinity immobilization
12
covalent affinity
8
immobilization methods
8
optimum amount
8
amount immobilized
8
immobilized aptamer
8
immobilization
7
biorecognition graphene
4
graphene physical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!