Characterization of candidate reference materials for bone lead via interlaboratory study and double isotope dilution mass spectrometry.

J Anal At Spectrom

Trace Elements Laboratory, Wadsworth Center, New York State Department of Health, P.O. Box 509, Albany, NY 12201, USA.

Published: November 2007

Four candidate ground bone reference materials (NYS RMs 05-01 through 04), were produced from lead-dosed bovine and caprine sources, and characterized by interlaboratory study. The consensus value ( X ) and expanded standard uncertainty (U(X) ) were determined from the robust average and standard deviation of the participants' data for each NYS RM 05-01 through 04. The values were 1.08 ±0.04, 15.3 ±0.5, 12.4 ±0.5, and 29.9 ±1.1 μg g(-1) Pb, respectively. Youden plots of z-scores showed a statistically significant correlation between the results for pairs of NYS RM 05-02 through 04, indicating common sources of between-laboratory variation affecting reproducibility. NYS RM 05-01 exhibited more random variability affecting repeatability at low concentration. Some participants using electrothermal atomic absorption spectrometry (ETAAS) exhibited a negative bias compared to the all-method consensus value. Other methods used included inductively coupled plasma mass spectrometry (ICP-MS), isotope dilution (ID-) ICP-MS, and ICP atomic (optical) emission spectroscopy (-OES). The NYS RMs 05-01 through 04 were subsequently re-analyzed in house using double ID-ICP-MS to assign certified reference values (C ) and expanded uncertainty (U(C) ) of 1.09 ± 0.03, 16.1 ± 0.3, 13.2 ± 0.3 and 31.5 ± 0.7, respectively, indicating a low bias in the interlaboratory data. SRM 1486 Bone Meal was analyzed for measurement quality assessment obtaining results in agreement with the certified values within the stated uncertainty. Analysis using a primary reference method based on ID-ICP-MS with full quantification of uncertainty calculated according to ISO guidelines provided traceability to SI units.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3477175PMC
http://dx.doi.org/10.1039/B710808GDOI Listing

Publication Analysis

Top Keywords

reference materials
8
interlaboratory study
8
isotope dilution
8
mass spectrometry
8
nys rms
8
rms 05-01
8
nys 05-01
8
nys
5
characterization candidate
4
reference
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?