Quantitative metabolic profiling is preceded by dedicated sample preparation protocols. These multistep procedures require detailed optimization and thorough validation. In this work, a uniformly (13)C-labeled (U(13)C) cell extract was used as a tool to evaluate the recoveries and repeatability precisions of the cell extraction and the extract treatment. A homogenous set of biological replicates (n = 15 samples of Pichia pastoris) was prepared for these fundamental experiments. A range of less than 30 intracellular metabolites, comprising amino acids, nucleotides, and organic acids were measured both in monoisotopic (12)C and U(13)C form by LC-MS/MS employing triple quadrupole MS, reversed phase chromatography, and HILIC. Recoveries of the sample preparation procedure ranging from 60 to 100% and repeatability precisions below 10% were obtained for most of the investigated metabolites using internal standardization approaches. Uncertainty budget calculations revealed that for this complex quantification task, in the optimum case, total combined uncertainty of 12% could be achieved. The optimum case would be represented by metabolites, easy to extract from yeast with high and precise recovery. In other cases the total combined uncertainty was significantly higher.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.201200447DOI Listing

Publication Analysis

Top Keywords

sample preparation
12
u13c cell
8
cell extract
8
repeatability precisions
8
optimum case
8
total combined
8
combined uncertainty
8
extract
4
extract pichia
4
pichia pastoris--a
4

Similar Publications

Investigation and elimination of noncovalent artificial aggregates during non-reduced capillary electrophoresis-sodium dodecyl sulfate analysis of a multi-specific antibody.

J Pharm Biomed Anal

January 2025

State Key Laboratory of Neurology and Oncology Drug Development, Nanjing, China; Simcere Zaiming Pharmaceutical Co, Ltd., Nanjing, China. Electronic address:

Capillary electrophoresis-sodium dodecyl sulfate (CE-SDS) is widely used in the biopharmaceutical industry for monitoring purity and analyzing impurities. The accuracy of the method may be compromised by artificial species resulting from sample preparation or electrophoresis separation due to suboptimal conditions. During non-reduced CE-SDS analysis of a multispecific antibody (msAb), named as multispecific antibody C (msAb-C), a cluster of unexpected peaks was observed after the main peak.

View Article and Find Full Text PDF

Serum metabolic fingerprinting on Ag@AuNWs for traumatic brain injury diagnosis.

Nanotechnology

January 2025

Xi'an Jiaotong University, xian ning west road 28#, xi'an, Xi'an, None Selected, 710049, CHINA.

Accurate and rapid diagnosis of traumatic brain injury (TBI) is essential for high-quality medical services. Nonetheless, the current diagnostic platform still has challenges in rapidly and accurately analysing clinical samples. Here, we prepared a highly stable, repeatable and sensitive gold-plated silver core-shell nanowire (Ag@AuNWs) for surface-enhanced Raman spectroscopy (SERS) metabolic fingerprint diagnosis of TBI.

View Article and Find Full Text PDF

Polydopamine-Mediated, Centrifugal Force-Driven Gold Nanoparticle-Deposited Microneedle SERS Sensors for Food Safety Monitoring Theoretical Study of the SERS Substrate Fabrication.

ACS Sens

January 2025

The Education Ministry Key Lab of Resource Chemistry, Shanghai Key Laboratory of Rare Earth Functional Materials, Shanghai Municipal Education Committee Key Laboratory of Molecular Imaging Probes and Sensors, and Department of Chemistry, Shanghai Normal University, Shanghai 200234, P. R. China.

Microneedle (MN) sensors have great promise for food safety detection, but the rapid preparation of MNs for surface-enhanced Raman scattering (SERS) sensors with tunable and homogeneous nanoparticles remains a great challenge. To address this, a SERS sensor of gold nanoparticles@polydopamine@poly(methyl methacrylate) MN (AuNPs@PDA@PMMA-MN) was developed. The extended-Derjaguin-Landau-Verwey-Overbeek theory was applied to calculate the interaction energy between AuNPs and PDA.

View Article and Find Full Text PDF

Impacts, Adaptations, and Preparedness Among SNAP-Ed Implementers During the COVID-19 Pandemic: A Multistate Study.

J Public Health Manag Pract

November 2024

Author Affiliations: Department of Health Promotion, Education, and Behavior, University of South Carolina, Columbia, South Carolina (Ms Draper, Dr Younginer, and Mr Samin); Center for Excellence in Public Health, University of New England, Portland, Maine (Dr Rodriguez and Ms Bruno); and Department of Nutrition and Food Sciences, University of Rhode Island, Providence, Rhode Island (Dr Balestracci).

Objective: The study examines: 1) impacts of COVID-19 on the work of Supplemental Nutrition Assistance Program - Education (SNAP-Ed) implementers, 2) facilitators and barriers experienced in making adaptations, and 3) factors that would have helped with preparedness to adapt.

Design, Setting, And Participants: A purposive sample of 181 SNAP-Ed program implementers from across five states completed a survey or interview based on the study aims. Quantitative data was summarized with descriptive statistics and qualitative data was analyzed thematically.

View Article and Find Full Text PDF

Identification of plant-based spilled oils using direct analysis in real-time-time-of-flight mass spectrometry with hydrophobic paper sampling.

Environ Monit Assess

January 2025

Science and Technology Branch, Pacific Environmental Science Centre, Environment and Climate Change Canada, Pacific and Yukon Laboratory for Environmental Testing, North Vancouver, BC, Canada.

Spilled plant-based oils behave very differently in comparison to petroleum oils and require different clean-up measures. They do not evaporate, disperse, dissolve, or emulsify to a significant degree but can polymerize and form an impermeable cap on sediment, smothering benthic media and resulting in an immediate impact on the wildlife community. The current study explored the application of rapid up-to-date direct analysis in real time (DART) with high-resolution mass spectrometry for plant-based oil typing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!