Peak capacity production is substantially improved for two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC×GC-TOFMS) and applied to the fast separation of a 28 component liquid test mixture, and two complex vapor samples (a 65 component volatile organic compound test mixture, and the headspace of warm ground coffee beans). A high peak capacity is achieved in a short separation time by selecting appropriate experimental conditions based on theoretical modeling of on-column band broadening, and by reducing the off-column band broadening by applying a narrow, concentrated injection pulse onto the primary column using high-speed cryo-focusing injection (HSCFI), referred to as thermal injection. A long, relatively narrow open tubular capillary column (20 m, 100 μm inner diameter (i.d.) with a 0.4 μm film thickness to benefit column capacity) was used as the primary column. The initial flow rate was 2 ml/min (60 cm/s average linear flow velocity) which is slightly below the optimal average linear gas velocity of 83 cm/s, due to the flow rate constraint of the TOFMS vacuum system. The oven temperature programming rate was 30°C/min. The secondary column (1.8m, 100 μm i.d. with a 0.1 μm film thickness) provided a relatively high peak capacity separation, concurrent with a significantly shorter modulation period, P(M), than commonly applied with the commercial instrument. With this GC×GC-TOFMS instrumental platform, compounds in the 28 component liquid test mixture provided a ∼7 min separation (with a ∼6.5 min separation time window), producing average peak widths of ∼600 ms full width half maximum (FWHM), resulting in a peak capacity on the primary column of ∼400 peaks (at unit resolution). Using a secondary column with a 500 ms P(M), average peak widths of ∼20 ms FWHM were achieved, thus providing a peak capacity of 15 peaks on the second dimension. Overall, an ideal orthogonal GC×GC peak capacity of ∼6000 peaks (at unit resolution) was achieved (or a β-corrected orthogonal peak capacity of ∼4400, at an average modulation ratio, M(R), of ∼2). This corresponds to an ideal orthogonal peak capacity production of ∼1000 peaks/min (or ∼700 peaks/min, β-corrected). For comparison, standard split/split-less injection techniques with a 1:100 split, when combined with standard GC×GC conditions typically provide a peak capacity production of ∼100 peaks/min, hence the instrumental platform we report provides a ∼7-fold to 10-fold improvement.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2012.09.096DOI Listing

Publication Analysis

Top Keywords

peak capacity
40
peak
12
high peak
12
capacity production
12
test mixture
12
primary column
12
capacity
11
two-dimensional gas
8
gas chromatography
8
time-of-flight mass
8

Similar Publications

Cardiorespiratory fitness in COPD and HF from the Fitness Registry and the Importance of Exercise: a National Database.

Eur Heart J Open

January 2025

Division of Cardiology, Department of Medicine, Université de Montréal, Montreal Heart Institute, 5000 Belanger Street, Montreal, Quebec, Canada H1T 1C8.

Aims: To better characterize functional consequences of the presence of COPD on cardiorespiratory fitness in patients with HF.

Methods And Results: Patients with any clinical indication for cardiopulmonary exercise testing (CPET) were included in the international FRIEND registry. Diagnosis of COPD was confirmed by a ratio of forced expiratory volume in 1 s and forced vital capacity (FEV/FVC) < 0.

View Article and Find Full Text PDF

Septoplasty-mediated improvements in nasal patency and pulmonary function: A prospective study.

Laryngoscope Investig Otolaryngol

February 2025

Otorhinolaryngology and Head and Neck surgery Unidade Local de Saúde de Santo António Porto Portugal.

Background And Objective: Septoplasty and turbinate reduction surgery (STR) is hypothesized to affect pulmonary function by modifying airway dynamics. This study investigates the impact of STR-mediated improvements in nasal patency on pulmonary function tests (PFTs).

Methods: In a prospective analysis, 37 adult patients undergoing STR were enrolled.

View Article and Find Full Text PDF

Objective: To evaluate the efficacy and safety of magnesium sulfate in the treatment of acute severe asthma in adults.

Methods: Literature searches were conducted on PubMed, Cochrane, CNKI, VIP and Wanfang databases to screen randomized controlled trial (RCT) of magnesium sulfate in the treatment of acute severe asthma in adults, starting from the establishment of the database and ending on May 22, 2024. The control group received conventional treatment.

View Article and Find Full Text PDF

Flexible zinc-air batteries (FZABs) present a promising solution for the next generation of power sources in wearable electronics, owing to their high energy density, cost-effectiveness, and safety. However, solid-state electrolytes for FZABs continue to face challenges related to rapid water loss and low ionic conductivity. In this study, a hydrophilic and stable tetramethylguanidine-modified graphene oxide as an additive, which is incorporated into sodium polyacrylate to develop a high-performance gel polymer electrolyte (GPE), is designed.

View Article and Find Full Text PDF

Background: Near-infrared spectroscopy (NIRS) enables a non-invasive measurement of tissue oxygen saturation (StO) in regions illuminated by near-infrared lights. Vascular occlusion test (VOT) serves as a model to artificially induce forearm ischemia-reperfusion. The combination of StO monitoring and VOT allows for dynamic evaluation of the balance between oxygen delivery and consumption in tissue, as well as the functional reserve of microcirculation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!