Levetiracetam-loaded biodegradable polymer implants in the tetanus toxin model of temporal lobe epilepsy in rats.

J Clin Neurosci

Centre for Clinical Neurosciences and Neurological Research, St. Vincent's Hospital Melbourne, P.O. Box 2900, Fitzroy, Victoria 3065, Australia.

Published: January 2013

Approximately one-third of people with epilepsy receive insufficient benefit from currently available anticonvulsant medication, and some evidence suggests that this may be due to a lack of effective penetration into brain parenchyma. The current study investigated the ability of biodegradable polymer implants loaded with levetiracetam to ameliorate seizures following implantation above the motor cortex in the tetanus toxin model of temporal lobe epilepsy in rats. The implants led to significantly shorter seizures and a trend towards fewer seizures for up to 1 week. The results of this study indicate that drug-eluting polymer implants represent a promising evolving treatment option for intractable epilepsy. Future research is warranted to investigate issues of device longevity and implantation site.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jocn.2012.05.017DOI Listing

Publication Analysis

Top Keywords

polymer implants
12
biodegradable polymer
8
tetanus toxin
8
toxin model
8
model temporal
8
temporal lobe
8
lobe epilepsy
8
epilepsy rats
8
levetiracetam-loaded biodegradable
4
implants
4

Similar Publications

Background: In order to increase the stability of tibial component in total knee arthroplasty (TKA), intramedullary stem extensions (SE) have been developed. The aim of this systematic review and meta-analysis is to address the critical knowledge gap on post-operative outcomes and complications rate comparison between tibial component with SE compared to the tibial component standard configuration (SC) in primary cemented TKA.

Methods: We conducted a comprehensive search of online databases, including Pubmed, Embase, ISI Web of science, Cochrane Library, and Scopus, using the following MeSH terms, (total knee arthroplasty) OR (TKA) OR (total knee replacement) AND (Tibial stem) OR (stem extension) OR (long stem).

View Article and Find Full Text PDF

Polydimethylsiloxane loaded capsaicin afflicts membrane integrity, metabolic activity and biofilm formation of nosocomial pathogens.

Microb Pathog

January 2025

Biofouling and Biofilm Processes Section, Water and Steam Chemistry Division, Bhabha Atomic Research Centre Facilities, Kalpakkam 603 102, India; Homi Bhabha National Institute, Anushaktinagar, Mumbai 400 094, India. Electronic address:

Biofilms constitute 80% of all nosocomial infections associated with invasive medical devices. Polydimethylsiloxane, a highly elastic, inert, non-reactive, biocompatible silicone polymer is widely used as implant biomaterial due to its non-toxic and low-immunogenic nature. Owing to its hydrophobicity, PDMS suffers from microbial adhesion.

View Article and Find Full Text PDF

Hypermagnesemia- and Hyperphosphatemia-Associated Cardiac Arrest after Injection of a Novel Magnesium-Based Bone Cement in Spinal Surgery.

J Am Acad Orthop Surg Glob Res Rev

January 2025

From the Department of Orthopaedic Surgery, Singapore General Hospital, Singapore (Dr. Loh, Dr. Ling, Dr. Jiang, and Lim) and the Department of Surgical Intensive Care, Division of Anaesthesiology and Perioperative Medicine, Singapore General Hospital, Singapore (Dr. Goh).

We report a case of pulseless electrical activity (PEA) associated with profound hypermagnesemia immediately after cementation of a novel magnesium-based cement in spine surgery. During T8 to T12 posterior instrumentation and decompression laminectomy for vertebral metastasis secondary to lung cancer, a 61-year-old Chinese woman developed sudden hypotension and went into PEA immediately after injection of a novel magnesium-based cement. Intraoperative fluoroscopic imaging did not show any notable cement extravasation.

View Article and Find Full Text PDF
Article Synopsis
  • A clinical trial tested the effectiveness of adding nanogold particles to denture bases made of polymethyl methacrylate (PMMA) against standard acrylic bases, focusing on their impact on bacterial growth.
  • Twenty-two male patients with no teeth received either traditional acrylic dentures or those enhanced with nanogold, and microbial growth was measured over time around the implants.
  • Results showed that dentures with nanogold significantly reduced bacteria counts (Candida albicans, Escherichia coli, and Streptococcus mutans) at 2, 4, and 6 months compared to traditional dentures, suggesting a promising improvement in oral hygiene.
View Article and Find Full Text PDF

Bioinspired conductive oriented nanofiber felt with efficient ROS clearance and anti-inflammation for inducing M2 macrophage polarization and accelerating spinal cord injury repair.

Bioact Mater

April 2025

School of Pharmacy, The Key Laboratory of Prescription Effect and Clinical Evaluation of State Administration of Traditional Chinese Medicine of China, Binzhou Medical University, Yantai, 264003, PR China.

Complete spinal cord injury (SCI) causes permanent locomotor, sensory and neurological dysfunctions. Targeting complex immunopathological microenvironment at SCI sites comprising inflammatory cytokines infiltration, oxidative stress and massive neuronal apoptosis, the conductive oriented nanofiber felt with efficient ROS clearance, anti-inflammatory effect and accelerating neural regeneration is constructed by step-growth addition polymerization and electrostatic spinning technique for SCI repair. The formation of innovative Fe-PDA-PAT chelate in nanofiber felt enhances hydrophilic, antioxidant, antibacterial, hemostatic and binding factor capacities, thereby regulating immune microenvironment of SCI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?