Movement of the distal carpal row during narrowing and widening of the carpal arch width.

J Biomech Eng

Departments of Biomedical Engineering, Cleveland Clinic, Cleveland, OH 44195, USA.

Published: October 2012

Change in carpal arch width (CAW) is associated with wrist movement, carpal tunnel release, or therapeutic tunnel manipulation. This study investigated the angular rotations of the distal carpal joints as the CAW was adjusted. The CAW was narrowed and widened by 2 and 4 mm in seven cadaveric specimens while the bone positions were tracked by a marker-based motion capture system. The joints mainly pronated during CAW narrowing and supinated during widening. Ranges of motion about the pronation axis for the hamate-capitate (H-C), capitate-trapezoid (C-Td), and trapezoid-trapezium (Td-Tm) joints were 8.1 ± 2.3 deg, 5.3 ± 1.3 deg, and 5.5 ± 3.5 deg, respectively. Differences between the angular rotations of the joints were found at ΔCAW = -4 mm about the pronation and ulnar-deviation axes. For the pronation axis, angular rotations of the H-C joint were larger than that of the C-Td and Td-Tm joints. Statistical interactions among the factors of joint, rotation axis, and ΔCAW indicated complex joint motion patterns. The complex three-dimensional motion of the bones can be attributed to several anatomical constraints such as bone arrangement, ligament attachments, and articular congruence. The results of this study provide insight into the mechanisms of carpal tunnel adaptations in response to biomechanical alterations of the structural components.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3594106PMC
http://dx.doi.org/10.1115/1.4007634DOI Listing

Publication Analysis

Top Keywords

angular rotations
12
distal carpal
8
carpal arch
8
arch width
8
carpal tunnel
8
pronation axis
8
td-tm joints
8
carpal
6
joints
5
movement distal
4

Similar Publications

Humerus de-rotational osteotomies are one of the commonly done salvage procedures in children with residual brachial plexus birth injuries. Conventionally, the degree of angular correction was measured clinically intraoperatively by the ability to reach the occiput and the belly or it can be measured by putting reference k-wires at the appropriate angles. However, accurate angular correction is essential to success, as under-correction may lead to parental dissatisfaction and over-correction may lead to loss of mid-line function.

View Article and Find Full Text PDF

We introduce a novel, to the best of our knowledge, method to achieve a highly efficient nonreciprocal magnon laser within a spinning cavity optomagnonic system, which integrates a magnon mode and two optical modes. The rotation of the YIG sphere triggers the Barnett effect in the magnon mode and the Sagnac effect in the optical modes. The directional input of a pump light leads to opposite Sagnac-Fizeau frequency shifts in these modes.

View Article and Find Full Text PDF

We present an algorithm that combines quantum scattering calculations with probabilistic machine-learning models to predict quantum dynamics rate coefficients for a large number of state-to-state transitions in molecule-molecule collisions much faster than with direct solutions of the Schrödinger equation. By utilizing the predictive power of Gaussian process regression with kernels, optimized to make accurate predictions outside of the input parameter space, the present strategy reduces the computational cost by about 75%, with an accuracy within 5%. Our method uses temperature dependences of rate coefficients for transitions from the isolated states of initial rotational angular momentum j, determined via explicit calculations, to predict the temperature dependences of rate coefficients for other values of j.

View Article and Find Full Text PDF

The cost of perspective switching: Constraints on simultaneous activation.

Psychon Bull Rev

January 2025

Department of Education and Psychology, The Open University, 1 University Road, P.O. Box 808, 4353701, Ra'anana, Israel.

Visual perspective taking often involves transitioning between perspectives, yet the cognitive mechanisms underlying this process remain unclear. The current study draws on insights from task- and language-switching research to address this gap. In Experiment 1, 79 participants judged the perspective of an avatar positioned in various locations, observing either the rectangular or the square side of a rectangular cube hanging from the ceiling.

View Article and Find Full Text PDF

The spin angular momentum (SAM) plays a significant role in light-matter interactions. It is well known that light carrying SAM can exert optical torques on micro-objects and drive rotations, but 3D rotation around an arbitrary axis remains challenging. Here, we demonstrate full control of the 3D optical torque acting on a trapped microparticle by tailoring the vectorial SAM transfer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!