The combination of high power laser beams with microfluidic delivery of cells is at the heart of high-throughput, single-cell analysis and disease diagnosis with an optical stretcher. So far, the challenges arising from this combination have been addressed by externally aligning optical fibres with microfluidic glass capillaries, which has a limited potential for integration into lab-on-a-chip environments. Here we demonstrate the successful production and use of a monolithic glass chip for optical stretching of white blood cells, featuring microfluidic channels and optical waveguides directly written into bulk glass by femtosecond laser pulses. The performance of this novel chip is compared to the standard capillary configuration. The robustness, durability and potential for intricate flow patterns provided by this monolithic optical stretcher chip suggest its use for future diagnostic and biotechnological applications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3470010 | PMC |
http://dx.doi.org/10.1364/BOE.3.002658 | DOI Listing |
Front Ophthalmol (Lausanne)
December 2024
Department of Biomedical Engineering, The Ohio State University, Columbus, OH, United States.
Introduction: Accommodation is the process of changing the ocular lens' refractive power and focal distance. This process involves application of biomechanical forces on the lens by the surrounding musculature. Previous studies have demonstrated that the lens epithelium demonstrates mechanotransduction and that tension influences its chemical activity.
View Article and Find Full Text PDFHardwareX
September 2024
Mechanical and Aerospace Engineering Department, University of California, Los Angeles, CA, USA.
The ability to simultaneously measure material mechanics and structure is central for understanding their nonlinear relationship that underlies the mechanical properties of materials, such as hysteresis, strain-stiffening and -softening, and plasticity. This experimental capability is also critical in biomechanics and mechanobiology research, as it enables direct characterizations of the intricate interplay between cellular responses and tissue mechanics. Stretching devices developed over the past few decades, however, do not often allow simultaneous measurements of the structural and mechanical responses of the sample.
View Article and Find Full Text PDFJ Synchrotron Radiat
July 2024
Institute for X-ray Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany.
X-rays can penetrate deeply into biological cells and thus allow for examination of their internal structures with high spatial resolution. In this study, X-ray phase-contrast imaging and tomography is combined with an X-ray-compatible optical stretcher and microfluidic sample delivery. Using this setup, individual cells can be kept in suspension while they are examined with the X-ray beam at a synchrotron.
View Article and Find Full Text PDFbioRxiv
May 2024
Mechanical and Aerospace Engineering Department, University of California, Los Angeles, CA, USA.
The ability to simultaneously measure material mechanics and structure is central for understanding their nonlinear relationship that underlies the mechanical properties of materials, such as hysteresis, strain-stiffening and -softening, and plasticity. This experimental capability is also critical in biomechanics and mechanobiology research, as it enables direct characterizations of the intricate interplay between cellular responses and tissue mechanics. Stretching devices developed over the past few decades, however, do not often allow simultaneous measurements of the structural and mechanical responses of the sample.
View Article and Find Full Text PDFModern X-ray free-electron lasers (XFELs) can generate pulses with durations ranging from femtoseconds to attoseconds. The numerical evaluation of ultra-short XFEL pulses through beamline systems is a critical process of beamline system design. However, the bandwidth of such ultra-short XFEL pulses is often non-negligible, and the propagation cannot be simply approximated using the central wavelength, especially in dispersive beamline systems.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!