Validation and perspectives of a femtosecond laser fabricated monolithic optical stretcher.

Biomed Opt Express

Istituto di Fotonica e Nanotecnologie (IFN)-CNR, Dipartimento di Fisica-Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy.

Published: October 2012

The combination of high power laser beams with microfluidic delivery of cells is at the heart of high-throughput, single-cell analysis and disease diagnosis with an optical stretcher. So far, the challenges arising from this combination have been addressed by externally aligning optical fibres with microfluidic glass capillaries, which has a limited potential for integration into lab-on-a-chip environments. Here we demonstrate the successful production and use of a monolithic glass chip for optical stretching of white blood cells, featuring microfluidic channels and optical waveguides directly written into bulk glass by femtosecond laser pulses. The performance of this novel chip is compared to the standard capillary configuration. The robustness, durability and potential for intricate flow patterns provided by this monolithic optical stretcher chip suggest its use for future diagnostic and biotechnological applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3470010PMC
http://dx.doi.org/10.1364/BOE.3.002658DOI Listing

Publication Analysis

Top Keywords

optical stretcher
12
femtosecond laser
8
monolithic optical
8
optical
6
validation perspectives
4
perspectives femtosecond
4
laser fabricated
4
fabricated monolithic
4
stretcher combination
4
combination high
4

Similar Publications

Influence of zonular tension on molecular transport in the porcine ocular lens.

Front Ophthalmol (Lausanne)

December 2024

Department of Biomedical Engineering, The Ohio State University, Columbus, OH, United States.

Introduction: Accommodation is the process of changing the ocular lens' refractive power and focal distance. This process involves application of biomechanical forces on the lens by the surrounding musculature. Previous studies have demonstrated that the lens epithelium demonstrates mechanotransduction and that tension influences its chemical activity.

View Article and Find Full Text PDF

The ability to simultaneously measure material mechanics and structure is central for understanding their nonlinear relationship that underlies the mechanical properties of materials, such as hysteresis, strain-stiffening and -softening, and plasticity. This experimental capability is also critical in biomechanics and mechanobiology research, as it enables direct characterizations of the intricate interplay between cellular responses and tissue mechanics. Stretching devices developed over the past few decades, however, do not often allow simultaneous measurements of the structural and mechanical responses of the sample.

View Article and Find Full Text PDF

X-ray phase-contrast tomography of cells manipulated with an optical stretcher.

J Synchrotron Radiat

July 2024

Institute for X-ray Physics, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany.

X-rays can penetrate deeply into biological cells and thus allow for examination of their internal structures with high spatial resolution. In this study, X-ray phase-contrast imaging and tomography is combined with an X-ray-compatible optical stretcher and microfluidic sample delivery. Using this setup, individual cells can be kept in suspension while they are examined with the X-ray beam at a synchrotron.

View Article and Find Full Text PDF

The ability to simultaneously measure material mechanics and structure is central for understanding their nonlinear relationship that underlies the mechanical properties of materials, such as hysteresis, strain-stiffening and -softening, and plasticity. This experimental capability is also critical in biomechanics and mechanobiology research, as it enables direct characterizations of the intricate interplay between cellular responses and tissue mechanics. Stretching devices developed over the past few decades, however, do not often allow simultaneous measurements of the structural and mechanical responses of the sample.

View Article and Find Full Text PDF

Modern X-ray free-electron lasers (XFELs) can generate pulses with durations ranging from femtoseconds to attoseconds. The numerical evaluation of ultra-short XFEL pulses through beamline systems is a critical process of beamline system design. However, the bandwidth of such ultra-short XFEL pulses is often non-negligible, and the propagation cannot be simply approximated using the central wavelength, especially in dispersive beamline systems.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!