A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Indoor radon monitoring near an in situ leach mining site in D G Khan, Pakistan. | LitMetric

Indoor radon and its decay products are considered to be the second leading cause of lung cancer after cigarette smoking. This is why extensive radon surveys have been carried out in many countries of the world, including Pakistan. In this context, 25 spots were selected at workplaces in the vicinity of the uranium mining site in Dera Ghazi Khan District for indoor radon measurement. For this purpose, CR-39 based radon detectors were installed at head height and were exposed to indoor radon for 60 days. After retrieval, these detectors were etched in a 6 M solution of NaOH at the temperature of 80 °C for 16 h in order to make the alpha particle tracks visible. The observed track densities were related to the indoor radon concentration using a calibration factor of 2.7 tracks cm(-2) h(-1)/kBq m(-3). The measured indoor radon concentration ranged from ∼386 ±161 to 3028 ± 57 Bq m(-3) with an average value of 1508 ± 81 Bq m(-3) in the studied areas of Dera Ghazi Khan District. The mean annual effective dose ranged from 2.22 ± 0.93 to 17.44 ± 0.33 mSv yr(-1), with an average of 8.68 ± 0.47 mSv yr(-1). The effect of the seasonal correction factor (SCF) on the annual average radon concentration has also been considered. Results of the current study show that, for the majority of the workplaces studied, indoor radon levels exceed the action levels proposed by many world organisations.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0952-4746/32/4/427DOI Listing

Publication Analysis

Top Keywords

indoor radon
28
radon concentration
12
radon
9
mining site
8
dera ghazi
8
ghazi khan
8
khan district
8
indoor
7
radon monitoring
4
monitoring in situ
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!