Truncated robust distance for clinical laboratory safety data monitoring and assessment.

J Biopharm Stat

Quantitative Sciences, GlaxoSmithKline Pharmaceuticals R&D, Collegeville, Pennsylvania 19426, USA.

Published: March 2013

Laboratory safety data are routinely collected in clinical studies for safety monitoring and assessment. We have developed a truncated robust multivariate outlier detection method for identifying subjects with clinically relevant abnormal laboratory measurements. The proposed method can be applied to historical clinical data to establish a multivariate decision boundary that can then be used for future clinical trial laboratory safety data monitoring and assessment. Simulations demonstrate that the proposed method has the ability to detect relevant outliers while automatically excluding irrelevant outliers. Two examples from actual clinical studies are used to illustrate the use of this method for identifying clinically relevant outliers.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10543406.2011.580483DOI Listing