We present an experimental study on the effect of polymer PVP on EOF mobility of microchannels wet etched into optical white soda lime glass, also known as Crown glass. We performed experiments to evaluate the effect of PVP concentration and pH on EOF mobility. We used on-chip capillary zone electrophoresis and a neutral fluorescent dye as a passive marker to quantify the electroosmotic flow. We performed experiments under controlled conditions by varying pH from 5.2 and 10.3 and concentration of PVP from 0 to 2.0% w/w at constant ionic strength (30 mM). Our experiments show that PVP at concentrations of 1.0% or above very effectively suppress EOF at low pH (6.6). At high pH of 10.3, PVP has a much weaker suppressing effect on EOF and increasing its concentration above about 0.5% showed negligible effect on EOF mobility. Finally, we briefly discuss the effects of pH on using PVP as an adsorbed coating. Our experiments provide useful guidelines on choosing correct pH and concentration of PVP for effective EOF suppression in glass channels.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.201200336DOI Listing

Publication Analysis

Top Keywords

eof mobility
12
pvp
8
performed experiments
8
concentration pvp
8
eof
6
pvp electroosmotic
4
mobility
4
electroosmotic mobility
4
mobility wet-etched
4
glass
4

Similar Publications

Article Synopsis
  • * Traditional CZE methods face challenges linking to mass spectrometry due to incompatible background electrolytes, but a new approach has been developed using a specific cationic coating and acidic background electrolyte to improve separation.
  • * The new CZE-ESI-MS method successfully distinguishes between various charge variants of mAbs, including specific forms of USP mAb003 and other antibodies like infliximab and adalimumab, showing its broad applicability in biopharmaceutical analysis.
View Article and Find Full Text PDF

Investigation of induced electroosmotic flow in small-scale capillary electrophoresis devices: Strategies for control and reversal.

Electrophoresis

October 2024

Department of Chemistry, Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, Kansas, USA.

Electroosmotic flow (EOF) is the bulk flow of solution in a capillary or microchannel induced by an applied electric potential. For capillary and microchip electrophoresis, the EOF enables analysis of both cations and anions in one separation and can be varied to modify separation speed and resolution. The EOF arises from an electrical double layer at the capillary wall and is normally controlled through the pH and ionic strength of the background buffer or with the use of additives.

View Article and Find Full Text PDF

Efficient separation of organic anions in beverages using aminosilane-functionalized capillary electrophoresis with contactless conductivity detection.

Anal Chim Acta

August 2024

Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama VI Rd., Bangkok, 10400, Thailand. Electronic address:

Background: Capillary electrophoresis (CE) has the advantage of rapid anion analysis, when employing a reverse electroosmotic flow (EOF). The conventional CE method utilizes dynamic coatings with surfactants like cetyltrimethylammonium bromide (CTAB) in the run buffer to reverse the EOF. However, this method suffers from very slow equilibration leading to drifting effective migration times of the analyte anions, which adversely affects the identification and quantification of peaks.

View Article and Find Full Text PDF

The unique properties of per- and polyfluoroalkyl substances (PFAS) have led to their extensive use in consumer products, including ski wax. Based on the risks associated with PFAS, and to align with PFAS regulations, the international ski federation (FIS) implemented a ban on products containing "C fluorocarbons/perfluorooctanoate (PFOA)" at all FIS events from the 2021/2022 season, leading manufactures to shift their formulations towards short-chain PFAS chemistries. To date, most studies characterising PFAS in ski waxes have measured a suite of individual substances using targeted analytical approaches.

View Article and Find Full Text PDF

We developed a simple, paper-based device that enables sensitive detection by mass spectrometry (MS) without solid phase extraction or other sample preparation. Using glass fiber filter papers within a 3D printed holder, the device employs electrokinetic manipulations to stack, separate, and desalt charged molecules on paper prior to spray into the MS. Due to counter-balanced electroosmotic flow and electrophoresis, charged analytes stack on the paper and desalting occurs in minutes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!