Comparison of pulsed versus continuous convective flow for central nervous system tissue perfusion: laboratory investigation.

J Neurosurg

Surgical Neurology Branch, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland 20892-1414, USA.

Published: December 2012

Object: Although pulsatile and continuous infusion paradigms have been described for convective delivery of drugs, the effectiveness and properties of each flow paradigm are unknown. To determine the effectiveness and properties of pulsatile and continuous convective infusion paradigms, the authors compared these convective flow methods in the gray and white matter of primates.

Methods: Six primates (Macaca mulatta) underwent convective infusion of Gd-DPTA (5 mM) into the cerebral gray matter (thalamus) or white matter (frontal lobe) using pulsed (intermittent pulses of 15 μl/min) or continuous (1 μl/min) convective flow. Results were assessed by clinical MRI and histological analyses.

Results: Distribution of Gd-DTPA infusate in gray and white matter by pulsed and continuous flow was clearly identified using MRI, which revealed that both convective flow methods demonstrated an increase in the volume of distribution (Vd) with increasing volume of infusion (Vi) in the surrounding gray and white matter. Although the mean (± SD) gray matter Vd:Vi ratio for the pulsed infusions (4.2 ± 0.5) was significantly lower than the mean Vd:Vi ratio for continuous infusions (5.4 ± 0.5; a 22% difference [p = 0.0006]), the difference between pulsed (3.8 ± 0.4) and continuous (4.3 ± 1.2) infusions in white matter was not significantly different (p = 0.3). Pulsed infusions were associated with more leakback (12.3% ± 6.4% of Vi) than continuous infusions (3.9% ± 7.8%), although this difference was not significant (p = 0.2). All animals tolerated the infusions and there was no histological evidence of tissue injury at the infusion sites.

Conclusions: Although pulsed and continuous infusion flow paradigms can be safely and effectively used for convective delivery into both gray and white matter, continuous infusion is associated with a higher Vd:Vi ratio than pulsatile infusion in gray matter. High rates of infusion (15 μl/min) can be used to deliver infusate without any significant leakback and without any clinical or histological evidence of injury.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4746716PMC
http://dx.doi.org/10.3171/2012.9.JNS12506DOI Listing

Publication Analysis

Top Keywords

white matter
24
convective flow
16
gray white
16
continuous infusion
12
gray matter
12
pulsed continuous
12
vdvi ratio
12
continuous infusions
12
continuous
10
infusion
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!