Satisfaction level of physicians who have undergone corneal refractive surgery.

Korean J Ophthalmol

Department of Ophthalmology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.

Published: October 2012

Purpose: To evaluate the levels of satisfaction among physicians who have undergone corneal refractive surgery.

Methods: This study included 212 eyes of 107 consecutive patients who underwent laser in situ keratomileusis or laser sub-epithelial keratomileusis surgery. Patients were divided into two groups: one group of physicians and one group of other healthcare workers (HCWs). The physicians' group was also subdivided into two different groups: surgeons or doctors using microscopes and medical physicians. The main outcome measures were scale scores obtained by using the Visual Function Index-14 questionnaires; uncorrected distance visual acuity (UDVA), residual spherical equivalent (SE), optical zone diameter, and residual corneal thickness were also compared between the groups.

Results: No significant differences in preoperative parameters, with the exception of the ratio of types of refractive surgery, were noted between the physicians and the HCWs group. Additionally, no differences between the groups were noted in the postoperative UDVA, residual SE, optical zone diameter, residual corneal thickness, and level of satisfaction. When comparing the two subgroups of physicians, the differences in satisfaction rates were not statistically significant, even in terms of the performance of delicate manual work.

Conclusions: No statistically significant differences in the clinical outcomes and satisfaction scores were detected after surgery between the physicians and HCWs groups, nor were any significant differences detected between the surgeons and medical physicians groups. Corneal refractive surgery can conceivably be recommended even for physicians who perform intensive near vision-dependent activities and delicate operations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3464316PMC
http://dx.doi.org/10.3341/kjo.2012.26.5.331DOI Listing

Publication Analysis

Top Keywords

corneal refractive
12
refractive surgery
12
physicians
9
physicians undergone
8
undergone corneal
8
medical physicians
8
udva residual
8
optical zone
8
zone diameter
8
diameter residual
8

Similar Publications

SMILE for correction of myopia in patients during the incipient phase of presbyopia.

Int Ophthalmol

January 2025

Department of Ophthalmology, Peking University Third Hospital, No 49 Huayuan North Road, Haidian District, Beijing, 100191, China.

Purpose: To evaluate clinical outcomes and visual quality 12 months after small incision lenticule extraction (SMILE) for correction of myopia with or without astigmatism in patients during the incipient phase of presbyopia.

Setting: Peking University Third Hospital, Beijing, China.

Design: Retrospective observation study.

View Article and Find Full Text PDF

Background/aims: To identify the risk factors for neuropathic corneal pain (NCP) following corneal refractive surgery and to report its clinical manifestations, imaging and proteomic characteristics.

Methods: This 1 year prospective cohort study included 100 eyes that underwent small incision lenticule extraction (SMILE) or laser-assisted in situ keratomileusis (LASIK). Ocular surface assessments, in-vivo confocal microscopy scans, tear neuromediators and proteomics analyses were performed.

View Article and Find Full Text PDF

Purpose: To present 4 family members with posterior polymorphous corneal dystrophy (PPCD), nonkeratoconic steep corneas, and myopia caused by a previously unknown genetic alteration in the ZEB1 gene.

Methods: Ophthalmic examinations and corneal curvature analyses were performed for all patients. Whole-exome targeted gene panel sequencing was performed for 1 patient.

View Article and Find Full Text PDF

This report explores the prevalence of keratoconus in a population-based cohort of adults aged 40 or older according to ten different definitions. All Rotterdam Study participants with reliable Pentacam scans and no prior corneal refractive surgery were cross-sectionally analysed (n = 2660). First, we applied a novel evidence-based definition.

View Article and Find Full Text PDF

To analyze the refractive accuracy of a novel swept-source optical coherence biometer (SS-OCT), that uses individual refractive indices to measure axial length, in short and long eyes implanted with monofocal intraocular lenses (IOLs). This retrospective comparative study considered eyes with short axial length (AL) (< 22.5 mm) or long AL (> 26 mm) bilaterally implanted with the Acrysof IQ monofocal IOL.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!