A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Benefits and limitations of cap-fitted colonoscopy in screening colonoscopy. | LitMetric

Background: Colonoscopy is widely used to detect colorectal cancer and to remove precancerous lesions to reduce the risk of colonic cancer.

Aims: To examine the benefits and limitations of cap-fitted colonoscopy compared to conventional colonoscopy in terms of technical performance and colorectal adenoma detection rate.

Methods: Screening colonoscopies performed from 2009 to 2010 with or without a transparent cap were retrospectively examined to compare the rate of successful intubation, cecal intubation time, and number, size, shape, and location of adenomas detected. An inclusion criterion was visualization of >95 % of the right colon.

Results: Data from 2,301 colonoscopies (1,165 with cap-fitted colonoscopy, 1,136 without the transparent cap) were retrospectively analyzed. Procedures were performed by four experienced endoscopists. The subjects' demographic characteristics and technical performances were similar between the two methods. The only significant difference in the technical performance between the two techniques was a shorter cecal intubation time with cap-fitted colonoscopy (5.3 vs. 6.6 min; p = 0.045) by one endoscopist. The total number of adenomas detected was significantly higher with cap-fitted colonoscopy than without the cap (586 vs. 484, respectively; p < 0.0001). Adenoma detection with cap-fitted endoscopy was significantly higher in the right colon than in the left colon (19 vs. 12 %, respectively; p = 0.0001).

Conclusion: Cap-fitted colonoscopy did not improve the technical aspects of colonoscopy but significantly increased adenoma detection, especially in the right colon. It did not increase the detection rate of flat or depressed adenomas.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10620-012-2403-1DOI Listing

Publication Analysis

Top Keywords

cap-fitted colonoscopy
24
adenoma detection
12
colonoscopy
10
benefits limitations
8
limitations cap-fitted
8
technical performance
8
transparent cap
8
cap retrospectively
8
cecal intubation
8
intubation time
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!