The management of pediatric and adolescent patients with pure aortic valve regurgitation remains challenging and controversial (Christos et al., Eur J Cardiothorac Surg 17:125-133, 2000; Gersony and Sommerville, ACC Curr J Rev 31:97-98, 2000; Hasaniya et al., J Thorac Cardiovasc Surg 127:970-974, 2004; Sabet et al., Mayo Clin 74:14-26, 1999; Tweddell et al., J Thorac Cardiovasc Surg 129:551-558, 2005). We evaluated pediatric and young adult patients who underwent aortic valve replacement (AVR) primarily for aortic regurgitation in an effort to identify preoperative echocardiographic variables that are predictive of left ventricular (LV) recovery following AVR. Twenty-one patients with severe aortic valve regurgitation who underwent AVR were identified. Retrospective chart review for each patient was performed and transthoracic echocardiograms prior to and 6-months after AVR were analyzed. Improvement in LV size based on preoperative LV end-systolic dimension index when compared to 6-months post-AVR was observed in 68% of the patients. Patients with persistent dilation of their left ventricles had a greater preoperative LV end-systolic dimension index (p ≤ 0.05), a greater preoperative LV end-systolic dimension z-score (p ≤ 0.002), and a lower preoperative ejection fraction (EF) (p ≤ 0.001). A similar trend was present between the two cohorts in regards to LV end-diastolic parameters (LV end-diastolic dimension index and z-score), with patients with abnormal LV size at 6-month follow-up having larger preoperative dimensions. Increasing LV systolic dimensions and declining EF appear to be predictors of poor LV recovery following AVR in pediatric and young adult patients. LV end-systolic indices appear to be more predictive than LV end-diastolic indices. AVR should be performed prior to severe LV enlargement defined as an LV end-systolic dimension z-score >4.5.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00246-012-0529-8 | DOI Listing |
The zebrafish is a valuable model organism for studying cardiac development and diseases due to its many shared aspects of genetics and anatomy with humans and ease of experimental manipulations. Computational fluid-structure interaction (FSI) simulations are an efficient and highly controllable means to study the function of cardiac valves in development and diseases. Due to their small scales, little is known about the mechanical properties of zebrafish cardiac valves, limiting existing computational studies of zebrafish valves and their interaction with blood.
View Article and Find Full Text PDFAnatol J Cardiol
January 2025
Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA ; Department of Cardiothoracic Surgery, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA.
Background: To evaluate the clinical outcomes of valve-in-valve transcatheter aortic valve replacement (ViV TAVR) with newer-generation self-expanding Evolut valves according to the size of the failed surgical bioprosthesis.
Methods: This single-center retrospective study evaluated consecutive patients undergoing ViV TAVR with the Evolut Pro/Pro+/Fx between 2018 and 2022. These patients were compared based on the true internal diameter (ID) of the failed bioprosthesis, specifically ≤19 mm (small group) vs.
Ann Noninvasive Electrocardiol
January 2025
Division of Cardiology, Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts, USA.
Background: Electrocardiograms (EKGs) are routinely performed in pregnant patients with pre-existing cardiovascular disease. However, in pregnant patients with congenital heart disease (CHD), EKG changes during gestation have not been explored.
Methods: We performed a retrospective study of pregnant patients with CHD enrolled in the STORCC initiative.
Gen Thorac Cardiovasc Surg Cases
January 2025
Department of Thoracic and Cardiovascular Surgery, Wakayama Medical University, 811-1 Kimiidera, Wakayama City, Wakayama, 641-8509, Japan.
Patients with coronary artery disease undergoing trans-catheter aortic valve implantation (TAVI) often receive TAVI alone. However, in cases of severe coronary lesions or anticipated difficulty in coronary access post-TAVI, percutaneous coronary intervention or coronary artery bypass grafting may be necessary. We performed simultaneous gastroepiploic artery to posterior descending artery bypass and TAVI in two patients with severe calcification of the right coronary artery ostium which is unsuitable for percutaneous intervention.
View Article and Find Full Text PDFCardiovasc Interv Ther
January 2025
Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka, 589-8511, Japan.
Transcatheter aortic valve implantation (TAVI) using the NAVITOR system has been relatively underreported due to its recent introduction in Japan. This study aimed to assess the short-term outcomes of TAVI with the NAVITOR in real-world clinical practice. Patients with severe aortic stenosis who underwent TAVI using the NAVITOR system at our institution between December 2022 and December 2023 were prospectively enrolled.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!