Purpose: Tibiofemoral contact kinematics or knee implant motions have a direct influence on patient function and implant longevity and should be evaluated for any new alignment technique such as kinematically aligned total knee arthroplasty (TKA). Edge loading of the tibial liner and external rotation (reverse of normal) and adduction of the tibial component on the femoral component are undesirable contact kinematics that should be minimized. Accordingly, this study determined whether the overall prevalence of undesirable contact kinematics during standing, mid kneeling near 90 degrees and full kneeling with kinematically aligned TKA are minimal and not different between groups of consecutive patients treated by different surgeons.
Methods: Three surgeons were asked to perform cemented, kinematically aligned TKA with patient-specific guides in a consecutive series of patients with their preferred cruciate-retaining (CR) implant. In vivo tibiofemoral contact positions were obtained using a 3- to 2-dimensional image registration technique in 69 subjects (Vanguard CR-TKA N = 22, and Triathlon CR-TKA N = 47).
Results: Anterior or posterior edge loading of the tibial liner was not observed. The overall prevalence of external rotation of the tibial component on the femoral component of 6 % was low and not different between surgeons (n.s.). The overall prevalence of adduction of the tibial component on the femoral component of 4 % was low and not different between surgeons (n.s.).
Conclusions: Kinematically aligned TKA minimized the undesirable contact kinematics of edge loading of the tibial liner, and external rotation and adduction of the tibial component on the femoral component during standing and kneeling, which suggests an optimistic prognosis for durable long-term function.
Level Of Evidence: III.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00167-012-2220-2 | DOI Listing |
J Exp Orthop
January 2025
Department of Orthopaedic Surgery, Faculty of Medicine The University of Tokyo Tokyo Japan.
Purpose: To clarify the influence of biomechanics on post-operative clinical outcomes in bicruciate-retaining total knee arthroplasty (BCR-TKA).
Methods: Severe medial osteoarthritis who underwent BCR-TKA were examined. Each patient was asked to perform a squat (weight-bearing [WB]) and active assisted knee flexion (non-WB [NWB]) under single fluoroscopy surveillance.
PeerJ
January 2025
Graduate School of Humanities and Social Sciences, Hiroshima University, Higashi-Hiroshima, Japan.
Background: Osoto-gari is a leg throw technique that primarily relies on the hip extension to initiate the sweeping motion of the leg. A high sweep contact velocity is a crucial factor in efficiently executing this technique. While some literature emphasises whole-body coordination in the leg-sweeping action, the roles of trunk and head motion remain unclear.
View Article and Find Full Text PDFSensors (Basel)
January 2025
German Center for Vertigo and Balance Disorders (DSGZ), LMU University Hospital, LMU Munich, 81377 Munich, Germany.
Instrumented gait analysis is widely used in clinical settings for the early detection of neurological disorders, monitoring disease progression, and evaluating fall risk. However, the gold-standard marker-based 3D motion analysis is limited by high time and personnel demands. Advances in computer vision now enable markerless whole-body tracking with high accuracy.
View Article and Find Full Text PDFAnn Biomed Eng
January 2025
Department of Bioengineering, Imperial College London, London, UK.
Purpose: People with unilateral transtibial amputation experienced a higher incidence of knee osteoarthritis due to abnormal movement patterns. This study aimed to explore alternations in muscle coordination to reduce mechanical burdens in their daily activities.
Methods: Five males with unilateral transtibial amputation were recruited.
Clin Biomech (Bristol)
January 2025
Department of Physical Education, Yonsei University, Republic of Korea. Electronic address:
Background: We aimed to synthesize the kinematics and kinetics during landing and walking/running tasks of ankle copers compared with patients with chronic ankle instability and controls.
Methods: We systematically searched PubMed, CINAHL, SPORTDiscus, and Web of Science. Tri-planar lower extremity biomechanics (joint angle and moment at maximum and initial contact, and joint displacement) were synthesized using standard mean difference and 95 % confidence intervals.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!