Undiluted blood samples are difficult to image in large volumes since blood constitutes a highly absorbing and scattering medium. As a result of this limitation, optical imaging of rare cells (e.g., circulating tumour cells) within unprocessed whole blood remains a challenge, demanding the use of special microfluidic technologies. Here we demonstrate a new fluorescent on-chip imaging modality that can rapidly screen large volumes of absorbing and scattering media, such as undiluted whole blood samples, for detection of fluorescent micro-objects at low concentrations (for example ≤50-100 particles/mL). In this high-throughput imaging modality, a large area microfluidic device (e.g., 7-18 cm(2)), which contains for example ~0.3-0.7 mL of undiluted whole blood sample, is directly positioned onto a wide-field opto-electronic sensor-array such that the fluorescent emission within the microchannel can be detected without the use of any imaging lenses. This microfluidic device is then illuminated and laterally scanned with an array of Gaussian excitation spots, which is generated through a spatial light modulator. For each scanning position of this excitation array, a lensfree fluorescent image of the blood sample is captured using the opto-electronic sensor-array, resulting in a sequence of images (e.g., 144 lensfree frames captured in ~36 s) for the same sample chip. Digitally merging these lensfree fluorescent images based on a maximum intensity projection (MIP) algorithm enabled us to significantly boost the signal-to-noise ratio (SNR) and contrast of the fluorescent micro-objects within whole blood, which normally remain undetected (i.e., hidden) using conventional uniform excitation schemes, involving plane wave illumination. This high-throughput on-chip imaging platform based on structured excitation could be useful for rare cell research by enabling rapid screening of large volume microfluidic devices that process whole blood and other optically dense media.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3485428PMC
http://dx.doi.org/10.1039/c2lc40894eDOI Listing

Publication Analysis

Top Keywords

large volumes
12
on-chip imaging
12
undiluted blood
12
blood
9
screening large
8
volumes blood
8
fluorescent on-chip
8
blood samples
8
absorbing scattering
8
imaging modality
8

Similar Publications

The evolution of preferred male traits, female preference and the G matrix: "Toto, I've a feeling we're not in Kansas anymore".

Heredity (Edinb)

January 2025

Department of Evolution, Ecology and Organismal Biology, 2710 Life Science Bldg, University of California, Riverside, CA, 92521, USA.

Female preference exerts selection on male traits. How such preferences affect male traits, how female preferences change and the genetic correlation between male traits and female preference were examined by an experiment in which females were either mated to males they preferred (S lines) or to males chosen at random from the population (R lines). Female preference was predicted to increase the time spent calling by males.

View Article and Find Full Text PDF

Background: Benzodiazepine abuse remains a significant public health concern. Current sample preparation methods for benzodiazepine analysis from human serum often involve complex procedures that require large sample volumes and extensive organic solvent use. To address these limitations, this study presents a novel and efficient sample preparation method utilizing 3D-printed sorbent devices.

View Article and Find Full Text PDF

Introduction of molecular point-of-care testing for SARS-CoV-2 in a triage unit of a large maternity hospital: An evaluation of staff experiences.

Infect Dis Now

January 2025

Department of Medical Microbiology and Virology. NHS Grampian, Aberdeen, UK. Electronic address:

Context: Recent advances in the development of rapid SARS-CoV-2 point of care (POC) testing provided an opportunity to aid clinical decision making in front-line healthcare settings. Perspectives of POC COVID-19 screening of pregnant women are under-researched.

Objective: To assess the impact of a SARS-CoV-2 POC testing platform implemented in a busy maternity hospital, with limited isolation capacity, during the third wave of the COVID-19 pandemic.

View Article and Find Full Text PDF

Background: A large urogenital hiatus in Level III results in a higher risk of developing pelvic organ prolapse after birth and failure after prolapse surgery. Deepening of the pelvic floor and downward rotation of the levator plate have also been linked to prolapse. Currently we lack data that evaluates how these measures relate to one another and to prolapse occurrence and size.

View Article and Find Full Text PDF

Background: The development of ST-segment elevation myocardial infarction (STEMI) in patients hospitalized for non-cardiac indications carries a high mortality rate.

Objectives: Determine the impact of rural vs. urban hospital location and hospital percutaneous coronary intervention (PCI) volumes on clinical outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!