Background: Pulmonary vein isolation (PVI) using cryoballoon (CB) catheter is a new technique for atrial fibrillation (AF) ablation. Previous studies used computer tomography (CT) or magnetic resonance imaging (MRI) scan to determine the pulmonary vein (PV) diameter and anatomy for choosing the CB size. We evaluated pre-ablation transoesophageal-echocardiography (TEE) as an alternative to CT/MRI scan in patients undergoing AF ablation for determining the appropriate size of the CB.
Methods: Fifty-five consecutive patients (men=43, women=12) with a mean age of 63 ± 12.5 years, and with drug-refractory paroxysmal AF (34 patients) or persistent AF (21 patients) were included in this prospective study. All patients underwent pre-ablation TEE.
Results: Hypertension was present in 19 patients (34%). Mean anterior-posterior left atrium diameter was 45.1 ± 8.9 mm. In total, 217 PV were targeted using a single 23-mm (n=14) or 28-mm (n=40) CB catheter chosen according to TEE-obtained measurements. PVI was achieved in 195 PV (90%). Mean number of CB applications per patient was 9.8 ± 2.1 (range 8-14). Mean procedure duration and fluoroscopy times were 131 ± 27 min (90-190 min) and 36 ± 12 min (22-66 min) respectively. Phrenic nerve palsy occurred in 3 patients (5.4%) and was transient (<1 month) in all of them.
Conclusion: This study suggests that TEE is an easily available and effective tool to select the size of the CB for PVI according to evaluated PV diameters and anatomy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijcard.2012.09.063 | DOI Listing |
Asia Ocean J Nucl Med Biol
January 2025
Department of Radiology, Tokushima University Hospital, Tokushima City, Japan.
We present two patients with a history of paroxysmal atrial fibrillation who developed pulmonary vein stenosis (PVS) following atrial fibrillation (AF) ablation. Case 1 involved a female patient in her 50s who was asymptomatic for pulmonary symptoms but was found to have a high degree of left superior PVS 15 months after AF ablation. This was demonstrated using contrast-enhanced computed tomography (CE-CT) and supported by findings of perfusion defects on ventilation-perfusion (V/Q) scan.
View Article and Find Full Text PDFHeart Rhythm
December 2024
University of Melbourne, Melbourne, Victoria, Australia; Royal Melbourne Hospital, Melbourne, Victoria, Australia; Baker Heart and Diabetes Research Institute, Melbourne, Victoria, Australia. Electronic address:
Background: Early recurrence of atrial tachyarrhythmia (ERAT) is common following catheter ablation of atrial fibrillation (AF). The specific clinical and arrhythmia characteristics of ERAT influencing late recurrence risk in persistent AF is unclear. Additionally, the impact of different ablation strategies on the incidence and prognostic significance of ERAT remains unknown.
View Article and Find Full Text PDFPulmonary vein anatomical variations are frequently observed in atrial fibrillation patients undergoing catheter ablation. However, when it comes to patients with atrial fibrillation and bilateral common ostium in the inferior pulmonary veins, using a bilateral circumferential pulmonary vein isolation approach during catheter ablation heightens the risk of esophageal injury. At present, there is no established standard catheter ablation strategy for such cases.
View Article and Find Full Text PDFCureus
December 2024
Orthopaedics, University of Central Florida, Orlando, USA.
Objective This study aims to utilize the TriNetX database, a comprehensive global network, to improve our understanding of the frequency, demographic factors, and related comorbidities of surgical patients who develop venous thromboembolism (VTEs) events. Methods The global collaborative network in TriNetX was queried for all cases from January 1, 2017, through December 31, 2023. International Classification for Disease (ICD) diagnosis codes were used to define patient cohorts with deep vein thrombosis (DVT) of the upper or lower extremity or pulmonary embolism (PE).
View Article and Find Full Text PDFCardiovasc Ther
January 2025
Department of Cardiology The Affiliated Hospital of Southwest Jiaotong University The Third People's Hospital of Chengdu Cardiovascular Disease Research Institute of Chengdu, Chengdu, Sichuan, China.
There is limited available data regarding the impact of cycle length (CL) prolongation when converting atrial fibrillation (AF) to organized atrial tachycardia (AT) and its effect on clinical outcomes. We retrospectively screened and included a cohort of 132 patients with persistent or long-standing persistent AF who underwent circumferential pulmonary vein isolation (CPVI) and left atrial substrate modification (LASM) between January 2015 and October 2019. In all 132 consecutive patients, persistent AF was successfully converted into organized AT.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!