Introduction: Electronic cigarette users ("vapers") inhale aerosols of water, nicotine, and propylene glycol (PG) or vegetable glycerin (VG). Aerosol particle sizes should affect deposition patterns in vapers and bystanders.
Methods: Aerosols were generated by a smoking machine and an electronic cigarette filled with 16mg/ml nicotine in aqueous PG or VG solution. A scanning mobility particle sizer (SMPS) counted particles of 10-1,000 nm diameters. A single puff experiment counted particles immediately and after aging 10 and 40 s. A steady-state experiment counted particles emitted from a collection chamber, untreated and after desiccation or organic vapor removal. The International Commission on Radiological Protection (ICRP) human respiratory tract model was used to estimate deposition. Results were compared to similar data from reference cigarettes.
Results: Puffs generated peak particle counts at (VG) 180 nm and (PG) 120 nm. Steady-state peaks occurred around 400 nm. Organic vapor removal eliminated small particles and reduced the size and number of large particles. Desiccation reduced the total volume of particles by 70% (VG, small PG) to 88% (large PG). The ICRP model predicted 7%-18% alveolar delivery; 9%-19% venous delivery, mostly in the head; and 73%-80% losses by exhalation. Reference cigarettes generated more particles initially, but were otherwise similar; however, in vivo smoke particle deposition is higher than the model predicts.
Conclusions: Nicotine delivery may depend on vaping technique, particle evolution, and cloud effects. Predicted 10% arterial and 15% venous delivery may describe bystander exposure better than vapers exposure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ntr/nts165 | DOI Listing |
J Orthop Surg Res
January 2025
Xuzhou Medical University Affiliated Stomatology Hospital, Xuzhou, 221002, Jiangsu Province, China.
Purpose: We aimed to explore the mechanism by which Boron-doped nano-hydroxyapatite (B-nHAp) facilitates the proliferation and differentiation of osteoblasts through controlled release of B.
Methods: B-nHAp characterization was accomplished by means of X-ray diffraction, scanning electron microscopy, inductively coupled plasma mass spectrometry, and transmission electron microscopy. Human bone marrow mesenchymal stem cells (hBMSCs) were subjected to flow cytometry, alizarin red S staining, and cell counting kit-8 assay for proliferation and differentiation determination.
Sci Rep
January 2025
Institute of Biology (Inbio), Universidade Federal de Mato Grosso do Sul, Campo Grande, MS, Brazil.
This study assessed the effect of composite resins, aggregated or not with S-PRG particles, and the use of toothpaste in controlling demineralization and bacterial growth. Human molars were distributed into 3 groups: control (CT) - sound teeth, Beautifil Bulk Restorative System (aggregated with S-PRG) (BB), Filtek One Bulk Fill (without S-PRG) (FB). Teeth destined for groups BB and FB previously received Class I preparations (4 × 4 × 4 mm), followed by single-increment restorations.
View Article and Find Full Text PDFJ Colloid Interface Sci
January 2025
Department of Mechanical and Aerospace Engineering, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, 278-8510, Chiba, Japan. Electronic address:
Hypothesis: Coherent structures by low-Stokes-number particles are induced within a closed flow, in which ordered flow regions known as Kolmogorov-Arnold-Moser (KAM) tori emerge. A variety of structures with different spatial characteristics has been predicted by varying the Stokes number, whereas the coexistence of structures in flow suspending various types of particles has not been hitherto demonstrated.
Experiments: Half-zone liquid bridges of O () are prepared as a closed system to induce thermocapillary-driven time-dependent flow under normal gravity conditions.
GMS Hyg Infect Control
December 2024
Institute of Hygiene and Environmental Medicine, University Medicine Greifswald, Germany.
Introduction: Room air class (RC) Ib may be necessary for surgical procedures in aseptic working areas. The aim of the study was to examine whether a mobile, three-stage sterile ventilation unit (MSVU) can replace a room ventilation system (RVS) with turbulent mixed flow (TMF) in the area of the operating field and on the instrument table from hygienic-microbiological point of view.
Method: During 26 surgeries (varicose vein stripping or treatment of umbilical and inguinal hernias), the microbial load was recorded at 4 measuring points (M1-M4) during regular operations by setting up sedimentation plates and measuring the particle concentration.
GMS Hyg Infect Control
December 2024
Clinical Microbiology Research Center, Ilam University of Medical Sciences, Ilam, Iran.
Background: Meningitis is highly prevalent in infant because their immune system is immature and they have less resistance to diseases. Among bacterial agents, is recognized as one of the most important causes of meningitis in infants.
Case Presentation: Herein, we report a case of late-onset meningitis, caused by (Patient:17-day-old female infant).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!