Purpose: To evaluate the use of perfluoropropane gas (C3F8) versus silicone oil (SO) for retinal detachment secondary to macular hole in patients with high myopia and posterior staphyloma.

Methods: In a retrospective study, 30 eyes of 30 patients underwent pars plana vitrectomy, and C3F8 (17 patients) or SO (13 patients) tamponade; internal limiting membrane peeling was performed successfully at the first surgery in 23 patients. High-density silicone oil tamponade was used for reoperations.

Results: The mean values of patients' characteristics were as follows: age, 57.7 years; axial length, 29.02 mm; spherical equivalent refraction, -15.40 diopters; initial best-corrected visual acuity, 2.35 logarithm of the minimum angle of resolution; final best-corrected visual acuity, 1.59 logarithm of the minimum angle of resolution. In C3F8 group, best-corrected visual acuity significantly improved (P < 0.001), passing from 2.34 to 1.36 logarithm of the minimum angle of resolution. Vision improvement from blindness to low vision was significantly greater (P = 0.009) in C3F8 group (16 of 17; 94%) than in SO group (6 of 13; 46%). A significant higher initial success (P = 0.025) was found in the C3F8 group (16 of 17; 94%) than in the SO group (7 of 13; 54%). Proliferative vitreoretinopathy was the cause of initial failure; all these subjects achieved anatomical success after being reoperated with high-density silicone oil tamponade.

Conclusion: C3F8 and internal limiting membrane peeling could represent the most effective strategy in highly myopic patients with macular hole retinal detachment. Other tamponade agents must be investigated.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IAE.0b013e3182670fd7DOI Listing

Publication Analysis

Top Keywords

silicone oil
16
macular hole
12
retinal detachment
12
best-corrected visual
12
visual acuity
12
logarithm minimum
12
minimum angle
12
angle resolution
12
c3f8 group
12
hole retinal
8

Similar Publications

Ocular hypertension after silicone oil filling surgery for high myopia: a case-control study.

BMC Surg

January 2025

Chongqing Nanping Aier Ophthalmology, 249 Nancheng Avenue, Nanan District, Chongqing, P. R. China.

Purpose: This study aims to examine the correlation between specific clinical parameters, such as axial eye length, and the onset of ocular hypertension "OH" following the use of silicone oil filling in patients with high myopia.

Method: In this retrospective analysis, we reviewed 214 eyes from 432 patients diagnosed with severe myopia, all of whom underwent vitrectomy and were treated with silicone oil filling. The study aimed to document the incidence and timing of postoperative ocular hypertension "OH" while assessing various factors, including demographic details, medical history, additional surgical interventions, and findings from supplementary examinations (such as axial length, silicone oil emulsification, and anterior chamber penetration).

View Article and Find Full Text PDF

Multifunctional aluminum alloy slippery liquid-infused surface with porous and boehmite nanoflower structure.

J Colloid Interface Sci

December 2024

Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China; State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China. Electronic address:

The depletion of lubricants in (slippery liquid-infused porous surfaces) SLIPS poses a significant challenge to their long-term functionality. While line-shaped rough structures can mitigate lubricant loss to some extent, they often fail to provide the stability required for sustained performance. In this study, we present a novel porous nanoflower aluminum alloy slippery liquid-infused surface (P-NF-AA SLIPS), which integrates a porous framework with a rough nanoflower structure.

View Article and Find Full Text PDF

Purpose: The emulsification of silicone oil (SO) remains poorly understood. In the present study, we investigated the physical properties of unused pharmaceutical SO samples under various conditions. Moreover, clinical correlations with the patients' SO samples were assessed.

View Article and Find Full Text PDF

Purpose: This report describes the use of the injectable intravitreal fluocinolone acetonide 0.18mg implant (FAI) for chronic postoperative cystoid macular edema (CME) in an eye with a silicone oil-filled vitreous cavity.

Methods: A retrospective chart review was performed including surgical, clinical, and imaging data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!