Background: Collecting electrophysiological and molecular data from the murine conduction system presents technical challenges. Thus, only little advantage has been taken of numerous genetically engineered murine models to study excitation through the cardiac conduction system of the mouse.

Objective: To develop an approach for isolating murine cardiac Purkinje cells (PCs), to characterize major ionic currents and to use the data to simulate action potentials (APs) recorded from PCs.

Methods: Light microscopy was used to isolate and identify PCs from apical and septal cells. Current and voltage clamp techniques were used to record APs and whole cell currents. We then simulated a PC AP on the basis of our experimental data.

Results: APs recorded from PCs were significantly longer than those recorded from ventricular cells. The prominent plateau phase of the PC AP was very negative (≈-40 mV). Spontaneous activity was observed only in PCs. The inward rectifier current demonstrated no significant differences compared to ventricular myocytes (VMs). However, sodium current density was larger, and the voltage-gated potassium current density was significantly less in PCs compared with myocytes. T-type Ca(2+) currents (I(Ca,T)) were present in PCs but not VMs. Computer simulations suggest that I(Ca,T) and cytosolic calcium diffusion significantly modulate AP profile recorded in PCs, as compared to VMs.

Conclusions: Our study provides the first comprehensive ionic profile of murine PCs. The data show unique features of PC ionic mechanisms that govern its excitation process. Experimental data and numerical modeling results suggest that a smaller voltage-gated potassium current and the presence of I(Ca,T) are important determinants of the longer and relatively negative plateau phase of the APs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4470703PMC
http://dx.doi.org/10.1016/j.hrthm.2012.10.002DOI Listing

Publication Analysis

Top Keywords

cardiac purkinje
8
conduction system
8
pcs
8
aps recorded
8
recorded pcs
8
plateau phase
8
current density
8
voltage-gated potassium
8
potassium current
8
pcs compared
8

Similar Publications

BACKGROUND Second-degree atrioventricular (AV) block is a frequently encountered conduction abnormality on surface electrocardiogram (ECG). However, it does not always imply a block at the AV nodal level. In rare cases, this block can occur below the bundle of His, within the infra-Hisian region of the His-Purkinje system.

View Article and Find Full Text PDF

A Matlab Toolbox for cardiac electrophysiology simulations on patient-specific geometries.

Comput Biol Med

December 2024

Research Center E. Piaggio, University of Pisa, L. Lazzarino, 1, Pisa, 56122, Italy; Information Engineering Department, University of Pisa, G. Caruso, 16, Pisa, 56122, Italy.

In this paper, we present CardioMat, a Matlab toolbox for cardiac electrophysiology simulation based on patient-specific anatomies. The strength of CardioMat is the easy and fast construction of electrophysiology cardiac digital twins from segmented anatomical images in a general-purpose software such as Matlab. CardioMat implements a quasi-automatic pipeline that guides the user toward the construction of anatomically detailed cardiac electrophysiology models.

View Article and Find Full Text PDF

Effect of excitation sequence of myocardial contraction on the mechanical response of the left ventricle.

Med Eng Phys

December 2024

Cardiopulmonary Regenerative Engineering (CARE) Group, Centre for Biological Engineering, Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, UK; Lower Saxony Center for Biomedical Engineering, Implant Research and Development, Hannover Medical School, Germany. Electronic address:

In the past two decades there has been rapid development in the field of computational cardiac models. These have included either (i) mechanical models that assumed simultaneous myocardial activation, or (ii) electromechanical models that assumed time-varying myocardial activation. The influence of these modelling assumptions of myocardial activation on clinically relevant metrics, like myocardial strain, commonly used for validation of cardiac models has yet to be systematically examined, leading to uncertainty over their influence on the predictions of these models.

View Article and Find Full Text PDF

Inositol 1,4,5-Trisphosphate Receptor 1 Gain-of-Function Increases the Risk for Cardiac Arrhythmias in Mice and Humans.

Circulation

December 2024

Department of Physiology and Pharmacology, Libin Cardiovascular Institute, University of Calgary, Canada (B.S., M. Ni, Y.L., Z.S., H.W., H.-L.Z., J.W., D.B., S.C., W.G., J.Y., S.T., J.P.E., R.W., S.R.W.C.).

Article Synopsis
  • * Researchers identified 21 human ITPR1 GOF variants and created a mouse model with one of these variants (ITPR1-W1457G), which was found to be prone to stress-induced ventricular arrhythmias.
  • * Both mouse models and human data suggest that ITPR1 GOF variants increase Ca handling abnormalities and arrhythmia risk, with 7 rare ITPR1 variants in a human database showing similar GOF behavior linked to cardiac
View Article and Find Full Text PDF
Article Synopsis
  • - Accurate diagnosis of wide QRS complex tachycardia (WCT) is crucial for effective treatment, with the earliest source often in the His-Purkinje system.
  • - Understanding the causes of WCT can significantly aid in determining the right treatment approach.
  • - The article discusses specific cases showing that aconitine poisoning is a potential cause of WCT, highlighting its importance in diagnosis.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!