Background: The introduction of different interocclusal recording materials has put clinicians in dilemma that which material should be used in routine clinical practice for precise recording and transferring of accurate existing occlusal records for articulation of patient's diagnostic or working casts in the fabrication of good satisfactory prosthesis. In the era of developing world of dentistry the different materials are introduced for interocclusal record with different brand names because of this; the utility of the material is confusing for successful delivery of prosthesis with lack of in vitro or in vivo studies which will predict the property of the material with utility recommendations.
Purpose Of The Study: The aim of this multicenter research is to evaluate the time dependent linear dimensional stability of three types of interocclusal recording materials; which gives very clear idea to clinicians in regard to its usage in routine practice and recommendations for usage of the different materials. Also to find out ideal time for articulation of three types of interocclusal recording materials with accuracy.
Materials And Method: Commercially available and ADA approved Polyether bite registration paste (Ramitec), Poly vinyl siloxane bite registration paste (Jetbite) and Zinc oxide eugenol (ZOE) bite registration paste (Super bite) were used in the study.A stainless steel die was made according to modified American dental Associations (ADA) specification no. 19. Each one of the tested materials were manipulated according to manufacturers' instructions. The materials separated from die, 3-mins after their respective setting time, resulted in disks of standard diameter. Two parallel lines and three perpendicular lines reproduced on the surface. The distance between two parallel lines was measured at different time intervals i.e. 1 hour, 24, 48 and 72 hours by using travelling microscope (magnus) and compared with standard die measurements made according to ADA specification no.19 to find out the dimensional stability of these interocclusal recording materials. Total 120 samples were made for observation and results were subjected to statistical analysis. Statistical analysis was performed using analysis of variance (ANOVA) and then Tukey's Honestly Significant Difference (HSD) test for comparison among groups at the 0.05 level of significance. After statistical analysis of the data, results were obtained and analyzed for interpretation.
Results: The results shows significant difference between the dimensional stability of all three material at different intervals with p-value <0.05. Comparatively the polyether bite registration material showed less distortion with good dimensional stability compared to Poly vinyl siloxane bite (Jetbite), Zinc oxide eugenol(ZOE) bite (Super bite) at 1 hour, 24, 48, and 72 hours.
Conclusion: The dimensional stability decreased with increase in time and is influenced by both material factor and time factor. Polyether was found to be more dimensionally stable interocclusal recording material, which was followed by Silicone and Zinc oxide eugenol (ZOE). The dimensional stability of Polyether was good. Zinc oxide eugenol is dimensionally more unstable when compared with polyether and polyvinyl siloxane. We recommend that the polyether interocclusal records must be articulated within 48 hours and Polyvinylsiloxane interocclusal records must be articulated within 24 hours and the ZOE should be articulated within 1 hour to get a correct restoration to have very minimum distortion and maximum satisfaction without failure of prosthesis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3489718 | PMC |
http://dx.doi.org/10.1186/1746-160X-8-27 | DOI Listing |
Polymers (Basel)
December 2024
Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia.
Interocclusal records (IORs) created with bite registration materials (BRMs) accurately reflect the opposing teeth's physiological and anatomical associations in digital and traditional dentistry. This study assessed the linear dimensional accuracy of vinyl polysiloxane-based scannable and transparent BRMs over obligatory clinical time intervals (1, 24, 72, and 168 h/s). A total of 3 scannable [Flexitime Bite, Occlufast CAD, Virtual CADBite] and 3 transparent [Maxill Bite, Charmflex Bite, Defend ClearBite] VPS-based BRMs were divided into 28 subgroups by time interval: 1, 24, 72, and 168 h/s.
View Article and Find Full Text PDFDent J (Basel)
October 2024
Department of Dental Prosthodontics, Faculty of Dental Medicine, "Carol Davila" University of Medicine and Pharmacy, 041313 Bucharest, Romania.
Aims: The aim of this study is to identify methods for the digital analysis of the closest speaking space in dentates and to assess certain particularities using digital analysis.
Method: For the adult patients included in this study, traditional dental casts were fabricated, and interocclusal registrations of the maximal intercuspal position and of the closest speaking space were taken using polyvinyl siloxane. Dental casts in both positions were scanned using a dental laboratory scanner, and digital analysis was conducted using the 3Shape 3D Viewer.
BMC Oral Health
November 2024
Fixed Prosthodontics Department, Faculty of Dentistry, Alexandria University, Roushdy, Sidi Gaber, Alexandria, Egypt.
Cureus
October 2024
Department of Prosthodontics and Crown and Bridge, Manav Rachna Dental College, Faridabad, IND.
Interocclusal registration is an essential step in oral rehabilitation. Conventionally, interocclusal registration has been conducted using interocclusal records made of wax or silicone. However, a digital method of registration utilizing an intraoral scanner has been introduced for analyzing inter-arch relationships.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!