Background: The United States FDA approved an over-the-counter HIV self-test, to facilitate increased HIV testing and earlier linkage to care. We assessed the accuracy of self-testing by untrained participants compared to healthcare worker (HCW) testing, participants' ability to interpret sample results and user-acceptability of self-tests in Singapore.
Methodology/principal Findings: A cross-sectional study, involving 200 known HIV-positive patients and 794 unknown HIV status at-risk participants was conducted. Participants (all without prior self-test experience) performed self-testing guided solely by visual instructions, followed by HCW testing, both using the OraQuick ADVANCE Rapid HIV 1/2 Antibody Test, with both results interpreted by the HCW. To assess ability to interpret results, participants were provided 3 sample results (positive, negative, and invalid) to interpret. Of 192 participants who tested positive on HCW testing, self-testing was positive in 186 (96.9%), negative in 5 (2.6%), and invalid in 1 (0.5%). Of 794 participants who tested negative on HCW testing, self-testing was negative in 791 (99.6%), positive in 1 (0.1%), and invalid in 2 (0.3%). Excluding invalid tests, self-testing had sensitivity of 97.4% (95% CI 95.1% to 99.7%) and specificity of 99.9% (95% CI: 99.6% to 100%). When interpreting results, 96%, 93.1% and 95.2% correctly read the positive, negative and invalid respectively. There were no significant demographic predictors for false negative self-testing or wrongly interpreting positive or invalid sample results as negative. Eighty-seven percent would purchase the kit over-the-counter; 89% preferred to take HIV tests in private. 72.5% and 74.9% felt the need for pre- and post-test counseling respectively. Only 28% would pay at least USD15 for the test.
Conclusions/significance: Self-testing was associated with high specificity, and a small but significant number of false negatives. Incorrectly identifying model results as invalid was a major reason for incorrect result interpretation. Survey responses were supportive of making self-testing available.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3444491 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0045168 | PLOS |
Antimicrob Steward Healthc Epidemiol
July 2024
Department of Pediatrics, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India.
Objective: We aimed to assess risk of COVID-19 infection & seroprotection status in healthcare workers (HCWs) in both hospital and community settings following an intensive vaccination drive in India.
Setting: Tertiary Care Hospital.
Methods: We surveyed COVID-19 exposure risk, personal protective equipment (PPE) compliance, vaccination status, mental health & COVID-19 infection rate across different HCW cadres.
PLOS Glob Public Health
January 2025
Department of Global Health, University of Washington, Seattle, Washington, United States of America.
Integrating and sustaining evidence-based interventions (EBIs) in routine care is crucial to improving HIV treatment outcomes among youth living with HIV (YLH). However, EBIs are often not sustained post clinical trial. An Adolescent Transition Package (ATP) delivered by health care workers (HCWs) and tested in Kenya in 2021 significantly improved YLH readiness to transition to independent care.
View Article and Find Full Text PDFJ Immunol Methods
January 2025
Cantonal Hospital St. Gallen, Clinic for infectious diseases and hospital hygiene, Switzerland; Children Hospital of Eastern Switzerland; Switzerland. Electronic address:
Background And Aims: Dried blood spots (DBS) have been proposed as a cost-effective surveillance method for population-wide screening of SARS-CoV-2 immunity but sensitivity of DBS based on self-collected DBS samples is unknown. To evaluate the success of vaccination strategies, it is necessary to differentiate vaccination from natural infection. Therefore, a test for antibodies against the viral nucleocapsid protein (anti-N) is desirable.
View Article and Find Full Text PDFPLoS One
December 2024
US Centers for Disease Control and Prevention, Atlanta, GA, United States of America.
Background: To optimize vaccination strategies, it is useful to detect breakthrough infections and assess vaccine effectiveness in programmatic use. Monitoring emerging SARS-CoV-2 variants and vaccine effectiveness against them is also essential to determine the most effective vaccine options. This study aims to monitor SARS-CoV-2 breakthrough infections, the emergence of new SARS-CoV-2 variants, and host immune response during the peri-infection period of COVID-19.
View Article and Find Full Text PDFPLoS One
December 2024
Clínica Colsanitas and Facultad de Medicina, Universidad Nacional de Colombia, Bogotá, Colombia.
Background: Despite declining COVID-19 incidence, healthcare workers (HCWs) still face an elevated risk of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) infection. We developed a diagnostic multivariate model to predict positive reverse transcription polymerase chain reaction (RT-PCR) results in HCWs with suspected SARS-CoV-2 infection.
Methods: We conducted a cross-sectional study on episodes involving suspected SARS-CoV-2 symptoms or close contact among HCWs in Bogotá, Colombia.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!