Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Myocardial perfusion SPECT (MPS) with software-assisted determination of summed stress score (SSS) is of established importance for diagnosis/therapy planning in coronary artery disease. Differences in contour finding suggest algorithm-specific influence on quantification if heart axes are chosen incorrectly. Thus, this study quantified the influence of heart-axis tilt on SSS calculation using Quantitative Perfusion SPECT and 4D-MSPECT.
Patients And Methods: Stress MPS of 50 men acquired on a triple-head gamma camera were correctly reoriented by experienced technologists (R0) and then tilted by 5 degrees/10 degrees/15 degrees/20 degrees/30 degrees/45 degrees along both long axes (R5-R45). SPECT images were quantified for SSS using QPS and 4D-MSPECT. SSS values for R0 and R5-R45 were analyzed using correlation analysis. Weighted kappa values (κ) were calculated to measure agreement regarding perfusion abnormality severity (4-step SSS rating: 0-3, 4-8, 9-13, and ≥14).
Results: For QPS SSS correlation, R0 vs. tilted datasets remained very high (R > 0.97) up to 20 degrees, but degraded for higher tilts (R = 0.895/0.780 for 30 degrees/45 degrees). 4D-MSPECT showed comparable SSS correlation only up to 10 degrees (R > 0.95) and strong deterioration thereafter (R = 0.863-0.347 for 15-45 degrees). Deviation in severity class from R0 increased from 6/50 (R5; κ = 0.914) to 25/50 (R45; κ = 0.252) using QPS and from 7/50 (R5; κ = 0.899) to 33/50 (R45; κ = 0.065) using 4D-MSPECT.
Conclusion: For tilted MPS datasets, considerable differences in SSS calculation emerge using QPS and 4D-MSPECT. QPS showed more stable results than 4D-MSPECT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/RLU.0b013e31826a8051 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!